RS1300003 Rev. 0
42
December 1997
Component Testing
Component
Description
Test Procedures
Switch, keyboard Semiconductor switch for control panel
keyboard.
Switch, SPDT
icemaker interlock
Interrupts connection to auger motor and
icemaker when freezer door is open.
Turns freezer light on when door is open.
In series with auger motor and
cube/crushed switch and freezer light.
Check resistance across terminals.
Continuity across terminals 1 and 2 – light
Continuity across terminals 1 and 3 – auger motor
Switch,
crushed/cubed
Selects between cubed or crushed ice
feature.
Check resistance across terminals.
Switch left
Middle terminal to left terminal
0 ohms
Middle terminal to right terminal
infinite ohms
Switch right
Middle terminal to right terminal
0 ohms
Middle terminal to left terminal
infinite ohms
Switch,
refrigerator light,
freezer light
Completes circuit to allow indicated
function. See technical data sheet and
wiring diagram for individual switch.
Check resistant across terminals.
Switch arm down
“NC” terminals
Closed
“NO” terminals
Open
Switch arm up
“NC” terminals
Open
“NO” terminals
Closed
Switch, power
Disconnects all power to unit when
switch if off (open.)
Unit shipped with switch on.
Check resistance across terminals
Switch,
photosensitive
In series with cavity light switch and
cavity light. Senses low light condition to
complete circuit to cavity light.
Switch must not generate line conducted
noise or radiate inference more than
three feet on the AM, FM, VHF, or USH
Frequency bands.
1.
To check light sensor with cavity light switch on, cover light sensor eye.
Cavity lamp should light at approximately 50% of full illumination.
2.
If lamp fails to illuminate, activate water or ice dispenser switch. Lamp
should illuminate at full illumination and water or ice should be dispensed.
3.
If light illuminates, disconnect power and replace light sensor.
4.
If lamp does not illuminate, disconnect power and check cavity lamp and
socket.
Thermistor
Senses temperatures within refrigerator
and freezer compartments.
Check resistance across terminals. See technical data sheet for bell curve
resistance chart at given temperatures.
PERIMETER
STATIC GUARD
Switch Functions
Enable Key
S1
S1 and Pin #3 and #4
Freezer Temperature
S2
S2 and Pin #3 and #6
Refrigerator Temperature
S3
S3 and Pin #3 and #7
Warmer
S4
S4 and Pin #6 and #7
Colder
S5
S5 and Pin #4 and #6
Vacation
S6
S6 and Pin #4 and #7
Max Cool
S7
S7 and Pin #7 and #8
Fast Freeze
S8
S8 and Pin #4 and #5
Alarm Off
S9
S9 and Pin #4 and #8
Display Off
S10
S10 and Pin #5 and #8