![Amana DS19 Service Download Page 29](http://html1.mh-extra.com/html/amana/ds19/ds19_service_2917692029.webp)
December 1997
29
RS1300003 Rev. 0
Temperature Offset Calibration
Offset amount adjusts temperatures for refrigerator
cut-ins and cut-outs by the amount of offset. The
chart below shows the indicator and the amount of
offset from the factory default setting.
INDICATOR
OFFSET
1
+8
2
+6
3
+4
4
+2
5
0
6
-2
7
-4
8
-6
Coldest
-8
•
Setting Refrigerator Temperature Offset
Press
Ref Temp pad. Refrigerator indicator and
one indicator will glow. Press
Warmer pad to
move offset to the next warmer setting. Press
Colder pad to move offset to the next colder
setting. Factory default refrigerator offset is +2.
•
Setting Freezer Temperature Offset
Press
Freezer Temp pad. Freezer temperature
indicator and one indicator will glow. Press
Warmer pad to move offset to the next warmer
setting. Press Colder pad to move offset to the
next colder setting. Factory default freezer offset
is 0.
Defrost Mode Selection
Toggle
Vacation pad to select adaptive or
conventional defrost mode. Vacation indicator glows
when adaptive defrost has been selected. If Vacation
indicator is off, conventional defrost is selected.
Conventional defrost uses 8 hour CRTD value.
Forced Defrost
Defrost can be forced to start by pressing and holding
the
Alarm Off pad for 3 seconds. Program changes
will be saved permanently in EEPROM and program
mode will exit to Run Mode.
Program Mode
Forced Pulldown (Compressor Start)
Compressor start can be forced by pressing and
holding
Fast Freeze pad for 3 seconds. Program
changes will be saved permanently in EEPROM.
Compressor, evaporator fan, damper heater, and
condenser fan will come on.
Exiting Program Mode
Press
*
pad for 3 seconds to exit Program Mode.
Tone will sound three times. Changes made in
Program Mode will be permanently saved in EEPROM.
NOTE: If no pad is pressed for 10 minutes, Program
Mode will be automatically exited. No changes
will be saved if Program Mode exits
automatically.