SS-DRYPTAC www.amana-ptac.com
7
6
www.amana-ptac.com SS-DRYPTAC
P
roduct
S
PecificationS
P
roduct
S
PecificationS
e
lecTric
h
eaT
P
erformance
d
aTa
Voltage
Electric
Heater Size
(kW)
No. of
Stages
Nominal Heating (BTU/h)
Total
Watts 5
Total
Amps 7
Min. Circuit
Amps ¹
MOD ³
(amps)
Power
Cord
@ 230V
@ 208V
230/208V
2.5/2.0
1
8,500
6,800
2,650/2,140
11.5/10.2
14.2
15
6 - 15 P
230/208V
3.5/2.9
1
12,000
9,900
3,650/3,040
15.8/14.5
19.6
20
6 - 20 P
Notes:
¹ Minimum branch circuit ampacity ratings conform to the National Electric Code; however, local codes should apply.
² Minimum voltage on 230/208-volt models is 197 volts; maximum is 253 volts.
³ Overcurrent protection for all units without electric heaters is 15 amps.
4
Heating capacity and efficiency based on unit operation without condensate pump; unit automatically switches to electric heat at approximately 24°F
outdoor ambient.
5
Total watts for 12,000 BTU/h models; subtract 70 watts for PT07/09*B**A*
6
Specify two-digit heater kW size to complete model number.
7
Total amps for 12,000 BTU/h models; subtract 0.2 amps for PT07/09*B*A*.
8
R-410A refrigerant used in all systems.
9
All units meet or exceed ASHRAE 90.1 standards.
10
All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards.
All units come with factory-installed power cords.
All units less than 250 volts come with LCDI device.
P
ower
r
ecePtacle
c
onfiguration
NEMA6-30R; 250V receptacle,
used on 230/208V units
G
NEMA7-30R; 277V receptacle,
used on 265V units
G
NEMA6-15R; 250V receptacle,
used on 230/208V units
G
NEMA6-20R; 250V receptacle,
used on 230/208V units
G
W
NEMA7-20R; 277V receptacle,
used on 265V units
G
250V Rating Power Cord Plugs with LCDI Device
NEMA 6 Configuration
P
ower
c
ord
P
lugs
15 amp
20 amp
30 amp
P
oWer
c
ord
c
onfiguraTion
c
onTracT
B
id
S
PecificaTionS
Please visit www.amana-ptac.com
to download the contractor bid specifications information.