WIRING DIAGRAMS
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
37
A/GPH1460M41A*
2
3
SEE NOTE 2
SEE NOTE 3
EM
TR
208-230
208-230/1/60
SUPPLY VOLTAGE
C
COMP
C
S.A
S
T1
R
L1
DF1
C
H
F
RCCF
CM
HVDR
T2
C
DF2
L2
1
L
3
1
2
R
W2
O
W1 Y1
G
C
EM
1
C
CSR
SEE NOTE 6
THERMOSTAT
N
G
2
3
CHS
CH
Y2
C
SOL
HP
S
24V
DC
DFT
Y
C
R
RVC
LPS
CNT
R-PS1
PS2
R
W
O
R-DFT
O-RV
C-RV
DFT
2 POLE ONLY
SEE NOTE 7
SEE NOTE 4
4
5
6
PLF
SEE NOTE 2
3
CONTROL
BOX
240
2
24V
208
TR
C
1
PU
WH
BR
BL
R
O
Y2
W2
W1
C
Y1
T2
T1
L1
GND
C
L2
BK
RD
RD
BK
BK
LVJB
RCCF
RD
SA
H
C
F
PU
YL
BK
BK
RVC
BK
COMP
S
C
R
CM
BR
PU
BK
YL
LPS
DFT
RD
YL
BK
YL
BL
HPS
BR
PU
BL
G
YL
YL
BL
SOL
YL
BL
CSR
4
LVTB
OR
WH
WH
BL
PK
1
2
3
YL
YL
YL
YL
BK
GR
BK
PU
10
11
12
7
8
9
4
5
6
3
2
1
BR
GR
GR
1
2
3
6
5
4
9
8
7
12
11
10
PU
PU
BR
BR
YL
PLM-P
GR
PU
BK
1
2
3
6
5
4
9
8
7
12
11
10
BR
BR
BR
YL
YL
BK
BK
PU
PU
PU
BK
PU
RD
RD
RD
BR
YL
BL
PU
BL
BL
RD
BL
BL
BL
BL
WH
WH
WH
PLF-C
PU
PU
PK
BL
BK
YL
PS2
C
C
R
C
Y
Y
R-PS
1
R-
DF
T
DF
T
0
CNT
CCR
HVDR
LVDR
W
C-RV
0-RV
0
DF
2
DF
1
R
DC
PU
BK
OR
RD
SEE NOTE 1
YL
SEE NOTE 7
SEE
NOTE 3
4
1
PLF-H
5
6
2
3
7
8
9
BL
BR
WH
GR
BK
PU
YL
BL
WH
C
L G N
1
2 3
EM
4 5
GR
10
11
12
7
8
9
4
5
6
3
2
1
PLM-B
SEE NOTE 2
BL
GR
YL
WH
NOTES :
1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INS
ULATION AS
ORIGINAL (AT LEAST 105˚C) USE COPPER CONDUCTO
R ONLY.
2. TO CHANGE EVAPORATOR MOTOR SPEED MOVE YELLOW AN
D WHITE
LEADS FROM EM"2" AND "3" TO "4" AND "5". IF BO
TH LEADS ARE
ENERGIZED, THE HIGHER SPEED SETTING IS USED.
3 FOR 208 VOLT TRANSFORMER OPERATION MOVE BLACK W
IRE
FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.
4. START ASSIST FACTORY EQUIPPED WHEN REQUIRED
5. USE COPPER CONDUCTORS ONLY
USE N.E.C. CLASS 2 WIRE
6. CRANKCASE HEATER AND CRANKCASE HEATER SWITCH FA
CTORY
EQUIPPED WHEN REQUIRED.
7. DOUBLE POLE CONTACTOR SHOWN. SINGLE POLE CONTA
CTOR
COULD BE FACTORY EQUIPPED AS AN ALTERNATE CONF
IGURATION.
SEE UNIT RATING PLATE FOR T
YPE AND SIZE
OF OVER CURRENT PRO
TECTION
FACTOR Y WIRING
LINE VOLTAGE
LOW VOLTAGE
OPTIONAL HIGH
VOLTAGE
FI E LD WIRING
HIGH VOLTAGE
LOW VOLTAGE
208/230/1/60
THERMOSTAT
SEE NOTE 5
SEE
NOTE 4
CH
RD
CHS
GR
BK PU
RD
BK
PLF-P
BK
SEE NOTE 6
BK
BL
BR
GR
OR
PU
RD
WH
YL
BLACK
BLUE
BROWN
GREEN
ORANGE
PURPLE
RED
WHITE
YELLOW
W IR E CODE
CONTACTOR
COMPRESSOR CONTACTOR RELAY
CRANKCASE HEATER
CRANKCASE HEATER SWITCH
CONDENSER MOTOR
COMPRESSOR
COMPRESSOR SOLENOID RELAY
DEFROST CONTROL
DEFROST THERMOSTAT
EVAPORATOR MOTOR
EQUIPMENT GROUND
HIGH PRESSURE SWITCH
HIGH VOLTAGE DEFROST RELAY
LOW PRESSURE SWITCH
LOW VOLTAGE DEFROST RELAY
LOW VOLTAGE JUNCTION BOX
LOW VOLTAGE TERMINAL BLOCK
FEMALE PLUG/CONNECTOR - CONTROL
FEMALE PLUG/CONNECTOR - HEAT KIT
FEMALE PLUG/CONNECTOR - PESSURE SWITCH
MALE PLUG/CONNECTOR - BLOWER
MALE PLUG/CONNECTOR - PRESSURE SWITCH
REVERSING VALVE COIL
RUN CAPACITOR FOR COMPRESSOR AND FAN
START ASSIST
TRANSFORMER
C
CCR
CH
CHS
CM
COMP
CSR
DC
DFT
EM
GND
HPS
HVDR
LPS
LVDR
LVJB
LVTB
PLF-C
PLF-H
PLF-P
PLM-B
PLM-P
RVC
RCCF
SA
TR
CO MPONENT L EGEND
208-230/1/60 0140G03223-C
SEE NOTE 5
SEE NOTE 1