ACCS
- remote input access. Allows the remote input to be used for setup function access control purposes.
Refer to the “ Accessing setup functions” in the Introduction chapter.
•
duII
- remote dulling of the display. When activated the display brightness will fall to the level set by the
dISP duII
level. This is generally used to reduce current consumption in battery powered applications
or for switching between day and night brightness levels.
•
ZERO
- zero the display. This mode allows the remote input to be used as a reset to zero input for the total
seen in the
tOtL
and
both
modes.
•
G.rSt
- grand total reset. This mode allows the remote input to be used as a reset input for the grand total
seen in the
tOtL
and
both
modes.
•
StoP
- totaliser inhibit - the total display value will be held and any input pulses ignored whilst the remote
input is short circuited. Not applicable to rate display.
5.37
Remote input 2 operation mode
Section:
R.INP
Display:
R.IN.2
Range:
NONE
,
P.HId
,
d.HId
,
P.Hi
,
P.Lo
,
Hi.Lo
,
AL.Ac
,
ACCS
,
duII
Default Value:
NONE
Default Access Level
4
Function number
4722
Remote input 2 functions. Same choices as
R.INP R.IN.1
apply.
5.38
Remote input 3 operation mode
Section:
R.INP
Display:
R.IN.3
Range:
NONE
,
P.HId
,
d.HId
,
P.Hi
,
P.Lo
,
Hi.Lo
,
AL.Ac
,
ACCS
,
duII
Default Value:
NONE
Default Access Level
4
Function number
4723
Remote input 3 functions. Same choices as
R.INP R.IN.1
apply.
5.39
Remote input 4 operation mode
Section:
R.INP
Display:
R.IN.4
Range:
NONE
,
P.HId
,
d.HId
,
P.Hi
,
P.Lo
,
Hi.Lo
,
AL.Ac
,
ACCS
,
duII
Default Value:
NONE
Default Access Level
4
Function number
4724
Remote input 4 functions. Same choices as
R.INP R.IN.1
apply.
44 of
LD5TMRMAN-1.1-0