3.5
Input connections
The START, STOP, REST TO ZERO and RESET TO PRESET inputs are on a small pcb on top of the
main pcb. The voltage between the EX+ and GND terminals (5, 12 or 18VDC) is determined by the
setting of the
P.Out
function and these terminals can alternatively be pulled down to ground by the
PULL UP
function.
INPUT 1
INPUT 2
GND
GND
EX+
EX+
IN
IN
D1
DIGITAL IN
GND
D2 D3
Start
Stop
Reset
Use momentary or latching switches to suit the mode
selected. Some modes do not use the Stop input.
The Reset input will reset the display to zero.
The Preset input will reset the display to the preset
value selected at the Preset function.
Preset
3.6
Input connections
The display will accept many common input sensor types. The input circuit is configured by the
IN1
functions (
IN2
functions are not applicable to this instrument). The common input types together with
typical
IN1
settings for these inputs are given below.
Inductive sensor input
IN1
function settings settings for inductive input
•
PULL UP
Set to
Lo
•
bIAS
Set to
OFF
•
Lo F
Set to
OFF
•
HYSt
Set to
OFF
for very low amplitude inputs (25mV to 250mV) or
On
for inputs with ampli-
tude 250mV to 48VDC or RMS