Timekeeper™
Users Manual
01/11/20
•
Turn the
Knob
to change the selected button delay value.
•
Press the
Select
button to advance to the button delay for IN4. The display will show "
4-00
".
•
Turn the
Knob
to change the selected button delay value.
- OR -
•
Wait 3 seconds, then press the
Test
button successively to select the desired button delay configuration
parameter.
•
To exit, press any button that changes the display mode or turn the power off and then on again.
The new values are stored in permanent memory. When the power is turned off and on, the values will be remembered.
Counter mode
This unit contains a counter with a range of 0 to 999999
Trigger the counter remote input (IN4) to increment the counter. Trigger the counter remote input (IN3) to decrement
the counter. Trigger the counter remote input (IN2) to reset the counter.
Setting Counter scale factors
When the scale factor is 1, each trigger of the counter remote input (IN3) increments or decrements the count by 1. For
example, it may be better to count by lots or cases of product. If the lot size is 75, set the scale factor to 75. Each
trigger of the Tallye input will count in lots of 75.
To set the scale factor:
•
Press the Counter
Up
button (input IN4) to select the counter mode.
•
Press and hold the
Select
button until the display changes.
•
Turn the
Knob
to set the lower two digits (xx00-xx99)
•
Press the
Select
button again.
•
Turn the
Knob
to set the upper two digits (00xx-99xx)
These settings can be saved into EEPROM by pressing and holding the stored settings button.
A momentary press of the stored settings button will recall the saved values.
Counter preset value for counter count down mode
Connect Inputs IN3 and IN4 together to the same button. Each time the button is pressed, the counter is loaded with the
preset value.
Each time the IN2 (count down) input, the count is decremented by the scale scale factor amount,
To load a preset value into the counter, perform the following steps:
•
Press the counter UP/Reset input IN3,IN4 to select the counter mode.
•
Turn the knob to set the middle two digits (xx00xx-xx99xx)
•
Press the select button again.
•
Turn the knob to set the upper two digits (00xxxx-99xxxx)
•
Press the select button.
•
Turn the knob to set the lower two digits (xxxx00-xxxx99)
VERSION=5C