8. TROUBLESHOOTING 

Please follow the guidelines below for common problems: 
 

 

Check UPS input plug and wiring. 

 

Check UPS input voltage. 

 

Please prepare the information as follows for service personnel: 

 

 

UPS model number and serial number 

 

Description of problem(s) in detail. 

 

8.1. General 

Problems 

 

Problems Possible 

causes 

Solution 

UPS has no reaction while 
AC power from utility is 
connected 

Fuse at back panel open 
No AC input 
UPS fault 
Battery failure 

Replace Fuse 
Check Utility AC power  
Call for service  
Call service center to replace batteries 

UPS has no reaction while 
AC power is connected, yet 
starts after pushing power 
on/off switch 

Fuse at back panel burnt  
No AC input  
UPS AC detecting circuit fail 
Check power cord 

Replace fuse 
Check Utility AC power  
Call for service 

UPS goes into back-up mode 
while connected to AC power 

Utility voltage or frequency 
abnormal  
UPS AC detecting circuit failure

Check AC power  
Call for service 

Battery can not provide 
normal back-up power in the 
event of a blackout 

Battery deteriorated 
Batteries not fully charged 
Battery charger damaged 

Charge batteries and reset 
If that doesn’t work call for service 

After AC connected to UPS, 
alarm sounds short and fast 
beeps and UPS shuts down 

Abnormal utility power 

Check input power 

Summary of Contents for Limousin II

Page 1: ...Always On UPS Systems Inc Limousin II Single Phase Input Single Phase Output Uninterruptible Power Supply 600VA User Manual Version 1 4...

Page 2: ...and performance of the UPS never load the UPS with a hair dryer heater laser printer or other types of inductive loads 9 The UPS has its own internal energy source battery therefore the output recepta...

Page 3: ...Switching Off the UPS 4 4 3 Self Test 4 4 4 Silence the Alarm 4 4 5 Cold Start 4 4 6 Green Function 4 5 AUDIBLE ALARM 5 5 1 Back Up Slow Alarm 5 5 2 Low Battery Rapid Alarm 5 5 3 Overload Continuous...

Page 4: ...eration of the UPS and the condition of the battery The Limousin provides two single phase 120VAC outlets for ease of connection to you equipment Overload protection is also a feature of this unit The...

Page 5: ...or more than 3 seconds to turn the UPS ON or OFF press and hold the button less than 1 second to activate a self test or silence the back up alarm Figure 2 1 Limousin Front Rear Panel 2 2 Rear Panel 3...

Page 6: ...load into the power outlets on the rear of the Limousin UPS To use the UPS as a master on off switch make sure all of the loads connected to the UPS are switched on CAUTION Never connect a laser print...

Page 7: ...to on line operation On completion of the test the LED stops flashing and remains on If the UPS fails the self test it immediately returns to on line operation If a failure occurred recharge the batte...

Page 8: ...test See replace battery section for battery replacement or call your dealer for services 6 SOFTWARE OPTIONS 6 1 UPSMON Software The UPSMON software uses the standard RS 232 interface to perform monit...

Page 9: ...open files before the battery reserves are exhausted 3 The ability to turn off the UPS 4 The ability to make the UPS perform a self test Some computers are equipped with a serial connector to link wit...

Page 10: ...r off and place it to the side The connecting wires and electronics will be exposed CAUTION Be careful not to touch any inner components of the Limousin UPS when changing the battery Electrical shock...

Page 11: ...center to replace batteries UPS has no reaction while AC power is connected yet starts after pushing power on off switch Fuse at back panel burnt No AC input UPS AC detecting circuit fail Check power...

Page 12: ...ealed Lead Acid Typical Recharge Time 4 hours to 90 of full capacity Protection Automatic self test discharge protection replace battery indicator BATTERY Back up Time 10 30 minutes depending on load...

Page 13: ...nups com Website www alwaysonups com 10 2 QA Warranty Questions Always On UPS Systems Inc Bldg 1 150 Campion Road Kelowna BC Canada V1X 7S8 Phone 250 491 9777 Ext 209 Fax 250 491 9775 Email qa alwayso...

Reviews: