Multirate and ATPC Parameters Menu
4.9
Multirate and ATPC Parameters Menu
In regular operation the transmitted signal is controlled by the ATPC mechanism.
The ATPC mechanism in the SU is controlled by the Base Station.
The Multirate and ATPC Parameters menu enable temporary control of the signal
transmitted by the SU. It is intended for test purposes only, when it may be
necessary to force the unit to transmit at a certain fixed power level.
These settings will not be saved and will automatically return to original values
as received from the Base Station when the units resets or upon exiting the
program (or upon termination).
The Multirate and ATPC Parameters menu includes the following options:
Show
Enable ATPC
Disable ATPC and Set Tx Power
4.9.1 Show
Select this option to view the current Multirate and ATPC parameters:
Last Tx Rate
Optimal Rx Rate: The current optimal rate for received signals.
ATPC: The current status current status (Enabled/Disabled) of the ATPC
mechanism
Tx Power: The current Tx power.
4.9.2 Enable
ATPC
Select this option to enable the ATPC mechanism after disabling it temporarily for
testing purposes.
4.9.3 Disable ATPC and Set Tx Power
Select this option to temporarily disable ATPC for testing purposes. You will be
prompted to enter the requested Tx Power. The available values for the Tx Power
are from –20dBm to 20dBm using a 1dBm resolution.
BreezeMAX PRO CPE
53