Chapter
3 - Commissioning
3.1
Configuring Basic Parameters
After completing the installation process, as described in the preceding chapter,
the basic parameters must be configured to ensure that the unit operates
correctly and can communicate with the AU. Once the basic parameters have
been configured, additional parameters can be remotely configured via the
wireless link.
To configure the SU’s basic parameters:
1
Connect a PC to the Ethernet port, using a straight Ethernet cable.
2
Configure the PC's IP parameters to enable connectivity with the unit. The IP
address of the Monitor program port is 192.168.254.251. The Subnet Mask is
255.255.255.0. The recommended IP address for the PC is 192.168.254.250,
as this is also the default TFTP Sever IP Address (required for downloading SW
versions and for downloading/uploading configuration files).
3
Run the Telnet program connecting to 192.168.254.251. The
Enter the
password
prompt
is displayed. Enter the password and press the Enter key.
NOTE
The default password is “installer”.
4
The Main menu of the SU Installer Monitor program is displayed, enabling
you to access the required parameters configuration and performance
monitoring options. Refer to Section
for instructions on using the SU
Installer Monitor program and detailed information on the various parameters
and other features supported by the program.
5
Configure the basic parameters listed in Table
6
Reset the unit (use the Reset option in the Unit Control menu) to apply the
new settings and enable synchronization with the AU.
BreezeMAX PRO CPE
24
Summary of Contents for BreezeMAX PRO CPE
Page 1: ...BreezeMAX BreezeMAX PRO CPE Manual S W Version 1 0 2 September 2005 P N 214094 ...
Page 2: ......
Page 8: ......
Page 10: ......
Page 14: ......
Page 16: ......
Page 38: ......
Page 46: ......
Page 73: ...A A Appendix A Preparing the SU IDU ODU Cable ...