Chapter
2 - Installation
Table 2-4: CPE-IDU-1D Connectors
Name
Connector
Functionality
ETHERNET (4)
(on the side panel)
10/100Base-T (RJ-45)
with 2 embedded LEDs
Connection to the user’s LAN/PC
Cable connection to a hub/switch/router: Crossed
Cable connection to a PC: Straight
RADIO
(on the front panel)
10/100Base-T (RJ-45)
Connection to the ODU
POWER
(on the bottom panel)
3-pin AC
Mains power connection
Table 2-5: CPE-IDU-1D LEDs
Name
Description
Functionality
POWER (3)
Power Indication
Off – IDU is not powered or power failed
Green – IDU power is OK
ETH (2)
Ethernet link status
(Ethernet integrity)
Off – No Ethernet connectivity has been detected
between the outdoor unit and the device
connected to the indoor unit
Green – Ethernet connectivity has been detected
between the outdoor unit and the device
connected to the indoor unit
WIRELESS (1)
Wireless link status
Off – SU is not associated with an AU/
µ
BST
Green – SU is connected with an AU/
µ
BST
* After power-up, the WIRELESS LED illuminates until self-test is finished.
2.2.4 SU-IDU
Installation
To install the SU-IDU:
1
It is assumed that the IDU-ODU cable is already connected to the ODU (refer
to Section
2.1.6.3
). Assemble an RJ-45 connector with a protective cover on
the indoor end of the IDU-ODU cable. Refer to
for instructions on
preparing the cable.
2
Connect the IDU-ODU cable to the RADIO connector. The RADIO connector in
the CPE-IDU-1D is located on the front panel as shown in Figure
2-3.
BreezeMAX PRO CPE
20