background image

 

eBridge200WPM/WPMH 

- 9 -

2.  If using a Static IP (recommended), you will need to input the information manually. In order for DDNS to work,

 

you must enter valid data, compatible with your network, for all of the network setting fields: IP address,

 

Subnet Mask, Inbound Port and Host Name.

3.  If you are connecting through a router, make sure that you have ‘opened up’ all the required network ports in the port

 

forwarding section of your router’s setup options. That is, you have directed the router to send any incoming traffic

 

using those IP ports to the LAN IP address of the eBridge200WPM/WPMH. Useful information about router port

 

forwarding can be found at www.portforward.com. Different routers may use different terms for port forwarding

 

function. For instance, D-Link calls it virtual server, Netopia calls it pinholes.

 

The default port for eBridge200WPM/WPMH is: 80

 

Note: Port 80 is the default port used for web browsing. Because of this, in order to prevent the average user from

 

hosting a web server, most ISPs BLOCK traffic using port 80 from reaching the average site. If you only plan to

 

monitor your eBridge200WPM/WPMH on a LAN, you can use port 80, and don’t have to concern yourself

 

with routers. However, if you desire remote access to your eBridge200WPM/WPMH, you MUST select functional 

 

ports and set up the port forwarding in your router. Other ports, such as 8080 and 8000, are sometimes blocked by

 

ISPs as well. What port(s) should be used? There are 65,535 valid IP ports to choose from.

 

These are broken down into three groups:

 

• Well Known Ports 0 through 1023.

 

• Registered Ports 1024 through 49151.

 

• Dynamic and/or Private Ports 49152 through 65535.

So, rather than encounter a port conflict by choosing a port commonly used for another purpose (like port 25 for SMTP 

mail or port 448 for secure sockets), choose an ‘unusual’ port number. For example, add 50,000 to your house number: 

50,123 is less likely to lead to a port conflict. For a list of the known and registered ports

see http://www.iana.org/assignments/port-numbers.

Summary of Contents for eBridge200WPM

Page 1: ...d LPS PoE Power Supply See input options table below Power Output 2 ports PoE PoE 30W per port or 1 port Hi PoE 60W Total output power 60W Ethernet Link Distance 500m max with Pace or eBridge100 series PoE receivers to eBridge200WPM or 100m with standard midspan or endspan to eBridge200WPM Connectivity RJ45 auto crossover Wire type 4 pair Cat 5 or better structured cable Device Distance 100m max e...

Page 2: ...5 Mount circuit board in enclosure with hardware 6 To facilitate wire entry utilize weather tight NEMA rated connectors supplied bushings and cable 7 Connect Coax from eBridge1SPR 100SPR 60W eBridge100RM eBridge400RM eBridge800RM or eBridge1600RM 60W receiver to connector marked COAX INPUT Fig 5 pg 3 Connect Cat5 from Pace1PRD 60W Pace1PRM Pace4PRM Pace8PRM Pace16PRM 30W receiver NetWay1D or Midsp...

Page 3: ...TY SPEED ACTIVITY SPR PoE DATA PoE SPR PoE DATA PoE 60W CAT 30W CAT or 60W COAX SW3 60W CAT 30W CAT or 60W COAX CAT 5e 100m CAT 5e 100m CAT 5e 100m Coax 300m Option 1 Option 2 30W Camera Device 30W Camera Device 60W Camera Device eBridge100SPR NetWay1D I T E 43KC www altronix com Input 51 56VDC Class 2 or LPS power supply Blue LED Coax link status SLOC RJ45 LEDs Yellow Speed Green Activity Green L...

Page 4: ...PoE www altronix com IP UTP Receiver Passes PoE PoE Pace1PRD Receiver 1 PORT 1 PORT 2 CAT INPUT COAX INPUT SPEED ACTIVITY SW3 SPEED ACTIVITY SPEED ACTIVITY SPR PoE DATA PoE SPR PoE DATA PoE 60W CAT 30W CAT or 60W COAX SW3 60W CAT 30W CAT or 60W COAX CAT 5e 100m Coax 300m Option 1 15W Camera Device eBridge100RM Midspan or Endspan RJ45 OUT PoE LED PoE LED Coax RJ45 LEDs Yellow Speed Green Activity Y...

Page 5: ...t5e 500m Pace1PRM Z1409 CAT 5e 100m CAT 5e 100m CAT 5e 100m Option 2 15W Camera Device 15W Camera Device 30W Camera Device Midspan or Endspan Option 1 1 PORT 1 PORT 2 CAT INPUT COAX INPUT SPEED ACTIVITY SW3 SPEED ACTIVITY SPEED ACTIVITY SPR PoE DATA PoE SPR PoE DATA PoE 60W CAT 30W CAT or 60W COAX SW3 60W CAT 30W CAT or 60W COAX Cat5e 100m CAT 5e 100m CAT 5e 100m CAT 5e 100m Option 2 15W Camera De...

Page 6: ... button then clicking Settings then clicking Network Connections b Right click the Local Area Connection Click Properties Administrator permission required If you are prompted for an administrator password or confirmation type the password or provide confirmation c Double click Internet Protocol TCP IP menu item d Choose the Obtain an IP address automatically option e Click OK Close all windows Fo...

Page 7: ...specify IPv4 IP address settings click Obtain an IP address automatically and then click OK e To specify IPv6 IP address settings click Obtain an IPv6 address automatically and then click OK Step 2 Connect a laptop or PC to the Ethernet port of the receiver Midspan or Endspan powering your eBridge200WPM WPMH The eBridge200WPM WPMH unit should be powered up at this moment Step 3 Open a browser wind...

Page 8: ...Inbound Port Port number for HTTP WEB communication Host Name Name of the eBridge200WPM WPMH device on the LAN Additional Information 1 If using DHCP all settings will be detected automatically While DHCP is a useful tool for determining the network settings if you set up your eBridge200WPM WPMH in this manner its IP address may change at different times for different reasons particularly after a ...

Page 9: ...rowsing Because of this in order to prevent the average user from hosting a web server most ISPs BLOCK traffic using port 80 from reaching the average site If you only plan to monitor your eBridge200WPM WPMH on a LAN you can use port 80 and don t have to concern yourself with routers However if you desire remote access to your eBridge200WPM WPMH you MUST select functional ports and set up the port...

Page 10: ...ghten the screw with flat head screwdriver or 5 16 hex socket driver Fig 18 pg 10 3 Attach the bottom bracket to the enclosure by inserting bolts through the flange of the enclosure and into the bracket tightening bolts with a 7 16 hex socket Fig 20 pg 10 4 Thread the second wormgear quick release strap through the slots on the back of the bottom mounting bracket Fig 17 pg 10 5 Mount enclosure ont...

Page 11: ...7 159 3mm 10 32 X 0 25 6 4mm 4 Places 4 25 108mm 4 35 110 5mm 6 0 152 4mm 6 75 171 5mm 8 75 222 2mm 8 75 222 2mm 316 Stainless Steel Padlock Latch Attached 0 375 9 5mm Padlock Eye 304 Stainless Steel Piano Hinge 9 32 236 7mm 4 92 125mm 4 0 101 6mm 9 5 241 3mm 0 312 7 9mm TYP 4 Places 0 65 16 5mm Holes 3 Places eBridge200WPMH ...

Page 12: ...9056 website www altronix com e mail info altronix com Lifetime Warranty Made in U S A IIeBridge200WP WPH WPM WPMH A14O MEMBER 1 Place unit at the desired location and secure with mounting screws not included Fig 16a and Fig 16b pg 9 Fig 16a Fig 16b Mechanical Drawing and Dimensions H x W x D approx 9 5 x 7 32 x 4 92 241 3mm x 185 9mm x 125mm Notes ...