background image

 

- 6 - 

eBridge200WPM/WPMH

15W Cat5e Application:

Fig. 12 - Data/Power Transmission from Headend up to 100m over Cat5e

Cable Type, Total Device Power, Data and Power Distance:

Cable Type

Total Power

Consumption

Max. Data

Distance

Max. Power

Distance

RG59u/23awg

15W

300m

264m

RG59u/23awg

30W

300m

132m

RG59u/23awg

60W

300m

66m

RG59u/22awg

15W

300m

334m

RG59u/22awg

30W

300m

167m

RG59u/22awg

60W

300m

83m

RG59u/20awg

15W

300m

532m

RG59u/20awg

30W

300m

266m

RG59u/20awg

60W

300m

133m

RG59u/18awg

15W

300m

846m

RG59u/18awg

30W

300m

423m

RG59u/18awg

60W

300m

211m

Cat-5e

15W

500m

846m

Cat-5e

30W

500m

423m

Cat-5e

60W

500m

211m

eBridge200WPM/WPMH User Interface and Programming:

Note: A constant PC connection is not required for proper operation and is used as a local programming/monitoring tool only.

Step 1.  Set Local Area Connection of your laptop to DHCP mode.

 

For Windows XP:

   

a. Open Network Connections by clicking 

Start button, then clicking Settings, then clicking Network Connections.

   

b. Right click the 

Local Area Connection. Click Properties. Administrator permission required.

   

  If you are prompted for an administrator password or confirmation, type the password or provide confirmation.

   

c. Double click 

Internet Protocol (TCP/IP) menu item.

   

d. Choose the 

Obtain an IP address automatically option.

   

e. Click 

OK. Close all windows.

 

For Windows Vista:

   

a. Open Network Connections by clicking the 

Start button Picture of the Start button, clicking Control Panel

     clicking 

Network and Internet, clicking Network and Sharing Center, and then clicking Manage Network

     connections.

1

PORT 1

PORT 2

CAT INPUT

COAX INPUT

SPEED

ACTIVITY

SW3

SPEED

ACTIVITY

SPEED

ACTIVITY

SPR

PoE

DATA

PoE

SPR

PoE

DATA

PoE

60W CAT

30W CAT

or

60W COAX

SW3

60W CAT

30W CAT

or

60W COAX

Cat5e - 100m

Midspan

or Endspan

CAT-5e - 100m

Option 1

15W Camera/Device

Note: Calculations based off of 56VDC starting
voltage from power source and accounts for a 10VDC 
voltage drop.  IEEE standards voltage range requirement 
for powered devices are:
PoE (15W)   - 37VDC to 57VDC
PoE+ (30W) - 44VDC to 57VDC

Summary of Contents for eBridge200WPM

Page 1: ...d LPS PoE Power Supply See input options table below Power Output 2 ports PoE PoE 30W per port or 1 port Hi PoE 60W Total output power 60W Ethernet Link Distance 500m max with Pace or eBridge100 series PoE receivers to eBridge200WPM or 100m with standard midspan or endspan to eBridge200WPM Connectivity RJ45 auto crossover Wire type 4 pair Cat 5 or better structured cable Device Distance 100m max e...

Page 2: ...5 Mount circuit board in enclosure with hardware 6 To facilitate wire entry utilize weather tight NEMA rated connectors supplied bushings and cable 7 Connect Coax from eBridge1SPR 100SPR 60W eBridge100RM eBridge400RM eBridge800RM or eBridge1600RM 60W receiver to connector marked COAX INPUT Fig 5 pg 3 Connect Cat5 from Pace1PRD 60W Pace1PRM Pace4PRM Pace8PRM Pace16PRM 30W receiver NetWay1D or Midsp...

Page 3: ...TY SPEED ACTIVITY SPR PoE DATA PoE SPR PoE DATA PoE 60W CAT 30W CAT or 60W COAX SW3 60W CAT 30W CAT or 60W COAX CAT 5e 100m CAT 5e 100m CAT 5e 100m Coax 300m Option 1 Option 2 30W Camera Device 30W Camera Device 60W Camera Device eBridge100SPR NetWay1D I T E 43KC www altronix com Input 51 56VDC Class 2 or LPS power supply Blue LED Coax link status SLOC RJ45 LEDs Yellow Speed Green Activity Green L...

Page 4: ...PoE www altronix com IP UTP Receiver Passes PoE PoE Pace1PRD Receiver 1 PORT 1 PORT 2 CAT INPUT COAX INPUT SPEED ACTIVITY SW3 SPEED ACTIVITY SPEED ACTIVITY SPR PoE DATA PoE SPR PoE DATA PoE 60W CAT 30W CAT or 60W COAX SW3 60W CAT 30W CAT or 60W COAX CAT 5e 100m Coax 300m Option 1 15W Camera Device eBridge100RM Midspan or Endspan RJ45 OUT PoE LED PoE LED Coax RJ45 LEDs Yellow Speed Green Activity Y...

Page 5: ...t5e 500m Pace1PRM Z1409 CAT 5e 100m CAT 5e 100m CAT 5e 100m Option 2 15W Camera Device 15W Camera Device 30W Camera Device Midspan or Endspan Option 1 1 PORT 1 PORT 2 CAT INPUT COAX INPUT SPEED ACTIVITY SW3 SPEED ACTIVITY SPEED ACTIVITY SPR PoE DATA PoE SPR PoE DATA PoE 60W CAT 30W CAT or 60W COAX SW3 60W CAT 30W CAT or 60W COAX Cat5e 100m CAT 5e 100m CAT 5e 100m CAT 5e 100m Option 2 15W Camera De...

Page 6: ... button then clicking Settings then clicking Network Connections b Right click the Local Area Connection Click Properties Administrator permission required If you are prompted for an administrator password or confirmation type the password or provide confirmation c Double click Internet Protocol TCP IP menu item d Choose the Obtain an IP address automatically option e Click OK Close all windows Fo...

Page 7: ...specify IPv4 IP address settings click Obtain an IP address automatically and then click OK e To specify IPv6 IP address settings click Obtain an IPv6 address automatically and then click OK Step 2 Connect a laptop or PC to the Ethernet port of the receiver Midspan or Endspan powering your eBridge200WPM WPMH The eBridge200WPM WPMH unit should be powered up at this moment Step 3 Open a browser wind...

Page 8: ...Inbound Port Port number for HTTP WEB communication Host Name Name of the eBridge200WPM WPMH device on the LAN Additional Information 1 If using DHCP all settings will be detected automatically While DHCP is a useful tool for determining the network settings if you set up your eBridge200WPM WPMH in this manner its IP address may change at different times for different reasons particularly after a ...

Page 9: ...rowsing Because of this in order to prevent the average user from hosting a web server most ISPs BLOCK traffic using port 80 from reaching the average site If you only plan to monitor your eBridge200WPM WPMH on a LAN you can use port 80 and don t have to concern yourself with routers However if you desire remote access to your eBridge200WPM WPMH you MUST select functional ports and set up the port...

Page 10: ...ghten the screw with flat head screwdriver or 5 16 hex socket driver Fig 18 pg 10 3 Attach the bottom bracket to the enclosure by inserting bolts through the flange of the enclosure and into the bracket tightening bolts with a 7 16 hex socket Fig 20 pg 10 4 Thread the second wormgear quick release strap through the slots on the back of the bottom mounting bracket Fig 17 pg 10 5 Mount enclosure ont...

Page 11: ...7 159 3mm 10 32 X 0 25 6 4mm 4 Places 4 25 108mm 4 35 110 5mm 6 0 152 4mm 6 75 171 5mm 8 75 222 2mm 8 75 222 2mm 316 Stainless Steel Padlock Latch Attached 0 375 9 5mm Padlock Eye 304 Stainless Steel Piano Hinge 9 32 236 7mm 4 92 125mm 4 0 101 6mm 9 5 241 3mm 0 312 7 9mm TYP 4 Places 0 65 16 5mm Holes 3 Places eBridge200WPMH ...

Page 12: ...9056 website www altronix com e mail info altronix com Lifetime Warranty Made in U S A IIeBridge200WP WPH WPM WPMH A14O MEMBER 1 Place unit at the desired location and secure with mounting screws not included Fig 16a and Fig 16b pg 9 Fig 16a Fig 16b Mechanical Drawing and Dimensions H x W x D approx 9 5 x 7 32 x 4 92 241 3mm x 185 9mm x 125mm Notes ...

Reviews: