CD200D II 4-17 Addendum
All rights reserved © ALTRONIC, LLC 2017
29
(Section 10)
10.10 Total Retard:
Indicates the total global timing retard at this time. This number is the sum
of the Insertion Retard, Switch Retard, Loop Retard, RPM Retard, and RMT
Global Retard (section 9.21.1).
(Section 12)
12.4 8 READ/WRITE CONFIGURATION BITS SUPPORTS WRITE SINGLE ONLY
READABLE IN MULTIPLES OF 8 BITS STARTING AT 8 BIT BOUNDARIES
ADDRESSES FUNCTION
00001
DISK ON CAM=0 CRANK=1
00002
TEST FOR PROPER DISK YES=1
00003
ENABLE SECONDARY DIAGS YES=1
00004***
reserved
00005***
reserved
00006
SLAVE
00007
reserved
00008
OFF = MAGNETIC Pickup ON = HALL-EFFECT Pickup
NOTE: READ/WRITE Functionality of Energy BIT 0 and BIT 1 in Standard
CD200D - 791090-x is replaced by READ/WRITE functionality of RMT Energy
Selection in CD200D Unit – 791090-xR (Remote Control) (TABLE 12.11)
12.5 4 READ/WRITE REGISTERS MIRROR COIL BITS
ADDRESSES FUNCTION
40001
REG40001=CoilBits 00016-00001
40002
REG40002=CoilBits 00032-00017
40003
REG40003=CoilBits 00048-00033
40004
REG40004=CoilBits 00064-00049
12.6 8 READ/WRITE REGISTERS REGARDING APPLICATION
ADDRESSES FUNCTION
40005
Disk+1 2,3,4,5,6,7,8,9,10,12
40006
Disk Lineup to TDC xx.x DEG
40007
Insertion Ret MIN=2.0 DEG
40008
Purge Delay Cycles 0-255
40009
RPM Over Speed Setpoint
40010
RPM Crank to Run Threshold
40011
Low Supply Voltage Limit
40012
SLAVE ANGLE xx.x DEG
12.7 3 READ/WRITE DEFAULT GLOBAL REGISTERS FOR ENGINE CONTROL
SYSTEM TABLE **
ADDRESSES FUNCTION
40014
Default Global Energy 0,1,2,3
40015
Default Global Timing Retard
40016
Default Individual Retard