CD200D II 4-17 All rights reserved © ALTRONIC, LLC 2017
18
FIGURE 2 — CD200D OPERATING VOLTAGE REQUIREMENT
8 x 1800 = 1.44 AMPS
8 x 1800 = 2.88 AMPS
RUNNING: 12-30 VDC
STARTING: 8 VDC MINIMUM
N = NO. FIRINGS PER ENGINE REVOLUTION.
CD200D UNIT
16-CYL. ENGINE, 1800 RPM
EXAMPLE:
I
5,000
AV
I
10,000
AV
AV
10,000
I = N x RPM
AV
5,000
I = N x RPM
24VDC UNIT
12VDC UNIT
FORMULA
GENERAL
BY NUMBER OF SYSTEMS.
FOR MULTIPLE SYSTEMS, MULTIPLY REQUIREMENTS
1. INFORMATION IS PER ONE (1) CD200D SYSTEM.
NOTE:
POWER SUPPLY SPECS: 25 AMP PEAK PULSES, 5 AMP CONTINUOUS.
D.C. POWER SOURCE
-
-
+
+
BAT.
BAT.
ALTERNATOR
REGULATOR
BAT. CHARGER
POWER SUPPLY
WIRE SIZE: 16 GA. (1.5 SQ. mm) MIN.
10 AMP
FUSE RATING:
10 AMP MIN.
RATING:
SWITCH
+
-
NOTE: CD200D HOUSING MUST BE
GROUNDED TO POWER SUPPLY NEGATIVE AND ENGINE BLOCK.
2. POWER SUPPLY NEGATIVE MUST BE
GROUNDED TO ENGINE BLOCK.
CD200D IGNITION
AVERAGE CURRENT = I
AV
CD200D UNIT