Roof Vent Installation
13
Once you have assembled the roof vents you can now install them to your building. Prepare the
ridge hinge (EV0314M) by running a bead of
silicone
along the back edge (diagrams 82 and 83).
Diagram 82
EV0314M
Then position this spaced equally over the opening in the roof.
Use the 13mm self taping screws (EV0329) to fix the hinge section
to the ridge cap, the screws will bore their own hole into the
aluminium as you screw. Secure one of the vent stops (D220) at
one end of the ridge hinge channel.
Next slide the roof vent along the channel of the ridge hinge from one end and secure with another
vent stop, diagram 84 and 85. You can now lower the vent until it rests on the roof bars.
D220
Ex
ternal
Silicone
Diagram 85
D22
0
Dia. 85
Diagram 84
Ex
ternal
Diagram 83