LTO
LTO
TM
Parameter Menus & System Set-up
Rs232
>
Port:
Shows the current Rs232 port (COM) used by the PC EDITOR and allows other choices to be selected,
if available on your computer.
Rs232
>
BAUD RATE:
Provides options to select the communication speed.
IMPORTANT
IMPORTANT
Reliable data transmission can usually be expected as long as the cable length is not more than 5 meters.
ADVANCED
ADVANCED
TIP
TIP
The RS232 serial port default speed is 9600 bits per second. In the
OPTIONS
menu it is possible to set a
speed of up to 115200 bits per second. If you experience transmission problems or disconnection, reduce
the speed of the serial data transmission.
First Steps with the PC EDITOR
To avoid accidentally overwriting an existing PRESET, it is important that you follow the correct routine when initiating a
session between TOTAL RECALL and your computer.
1] With TOTAL RECALL powered up and connected to your PC's serial port as described,
Run
the PC EDITOR program
by selecting the Tr EDITOR icon in the Windows PROGRAMS menu.
2] The PC EDITOR should now be loaded. A welcome screen will appear. This closes after 5 seconds (or click on it). Select
NEW from the FILE menu.
You will be presented with 2 options - NEW UNIT and NETWORK SCAN.
If your TOTAL RECALL has already been installed and set-up
and you now wish to view and/or modify some para-
meters, do the following:
Select
NETWORK SCAN
. The program will scan your PC's serial ports. When
Done
, it will present a list of IDs. The
ID
number
of TOTAL RECALL is
1
(this cannot be changed). The ID list will show if TOTAL RECALL (ID 1) is correctly
connected or not. Pressing
OK
will prompt
the system to retrieve (
UPLOAD
) all the parameters and all previously saved
USER PRESETS from TOTAL RECALL to your computer. A window will automatically open on your computer screen.
You can now view the settings and edit them (depending on the
Lock
mode).
R