CTP Combitherm
78
•
MN-35948
•
Rev 16
•
10/18
•
Combitherm® CT PROformance™ Series Operator’s Manual
Error
Code
Error Call Out in Display
Description of Error
Possible Cause(s)
E55
Vent Not Open (Lower vent on
dual vent system)
60 seconds aft er the venting
motor is activated the vent
motor safety switch did not
open.
— Alignment issue between motor cam and vent motor safety
switch (micro switch).
— Faulty vent valve (motor).
— Faulty vent valve safety switch (micro switch).
E56
Vent 2 Not Open (Upper vent
on dual vent system)
60 seconds aft er the venting
motor is activated the vent
motor safety switch did not
open.
— Alignment issue between motor cam and vent motor safety
switch (micro switch).
— Faulty vent valve (motor).
— Faulty vent valve safety switch (micro switch).
E57
No Rinse Water
Flow switch for solenoid valve Y4
does not detect any water flow
for a minimum of 60 seconds.
— Water supply is shut off .
— Low water pressure.
— Flow switch is dirty or defective.
— Double water solenoid valve defective (Y3).
— Relay board, high voltage, defective.
E88
Lower Gas Ignition Failure
NOTE: If aft er 2 attempts
to clear this error, the error
appears a third time, remove
the oven from service and
immediately contact an
Alto-Shaam authorized service
provider.
Reset output from Ignition
Module is ON
— Hot surface ignitor not functioning.
— No gas supply.
— Flame sensor not functioning.
— Faulty ignition control.
E89
Upper Gas Ignition Failure
NOTE: If aft er 2 attempts
to clear this error, the error
appears a third time, remove
the oven from service and
immediately contact an
Alto-Shaam authorized service
provider.
Reset output from Ignition
Module is ON
— Hot surface ignitor not functioning.
— No gas supply.
— Flame sensor not functioning.
— Faulty ignition control.
E90
Lower Gas Combustion Blower
Not at Speed
Speed is too slow.
— Power supply cable is not connected to blower motor.
— Speed control cable is not connected to blower motor.
— Blower motor is blocked, rotation is impeded, or motor is
faulty.
— Faulty control board.
E91
Upper Gas Blower Not at
Speed
Speed is to slow.
— Power supply cable is not connected to blower motor
— Speed control cable is not connected to blower motor
— Blower motor is blocked, rotation is impeded, or motor is
faulty
— Faulty control board
E92
Communication Error
CB does not properly respond
Twelve (12) instances of no-
response from the relay board
(CB) to the display board (IB).
— Check CAN cable connections.
— CAN cable defective.
— Relay board, low voltage, connector defective.
— Display board connector defective.
E93
Interface Board (IB) and
Control Board (CB) are in
diff erent states
The IB is in a diff erent running
state than the CB for more than
20 seconds.
— Check CAN cable connections.
— CAN cable defective.
— Relay board, low voltage, connector defective.
— Display board connector defective.
E94
Communication Error,
TO Interface Board
No signal transfer for more
than 20 seconds between the
Interface Board (IB) and the
Control Board (CB).
— Check CAN cable connections.
— CAN cable defective.
— Relay board, low voltage, connector defective.
— Display board connector defective.
Error Codes
continued on next page