Installation & User’s Manual
AP-150 RGBW Par LED Luminaire
s
20
Menu System
General Menu Options
Figure 22: General Menu Screen
Power Limit
When Power Limit is set to any value other than 100%, the unit will limit the luminaire’s output to the
setting. When this setting is active, the Green LED power indicator on the back of the luminaire will flash
slowly.
This setting will allow for specific upper threshold power settings. The power limit setting will “throttle back”
the output of the luminaire allowing the LED output to only reach the preset value. For example, if the
power setting is set to 50% only 50% of the output of each color will be available. See
Table 4
for details.
Table 4: Power Limit Setting (Current Draw)
Power up
Sets the luminaire’s state when the unit is initially powered. Setting options are:
• Color Filter (go to a color filter as selected and set by the user)
• Preset (go to a preset as selected and set by the user)
• Last Set (go to last setting)
Power Limit Setting
90%
80%
70%
60%
50%
40%
30%
20%
10%
Amperage at 120 Volts
0.76
0.67
0.60
0.52
0.43
0.36
0.28
0.20
0.14
Amperage at 230 Volts
0.40
0.36
0.32
0.28
0.23
0.19
0.15
0.11
0.07
Wattage Draw
92.79
82.47
73.13
63.29
53.34
43.63
33.80
24.70
16.84
General
> Power Limit
: 100%
• Power Up
: Last Set
• Calibration
: Off
• Rset Hours
: No
• BL Off Time
: 5 S