MULTITASKER™
400-0367-004
14
Example:
Adjust Input 1 volume level for the card in slot 5.
The current input level is 10, but it is not the
optimal value. After sending the following
commands, an optimum level of 5 is obtained:
1.
[SEL01C5]
The current input level is 10.
2.
[-] [-] [-] [-] [-] or [
-
5 ]
The level is now 5.
20.
[VOL]
This command sets the absolute volume level
for a given input.
Command Format: [VOLmmAvCnUi]
mm = Input (2 digit # from 01 to 64)
Av = Volume Level (# from 01 to 32)
Cn = Card ID (n = slot # from 1 to max slots)
Ui
= Unit ID (i = # from 0 to 9)
Example:
Set the volume level for Input 20, of the engine
card in slot 5, to a level of 16 using the
command [VOL20A16C5].
21.
[SDI]
This command is used to detect if there is a
signal present on one input or all inputs.
Command Format, One Input:
[SDImmCnUi]
Command Format, All Inputs:
[SDICnUi]
mm = Input (2 digit # from 01 to 64)
Cn = Card ID (n = slot # from 1 to max slots)
Ui
= Unit ID (i = # from 0 to 9)
Feedback Format: [IxxSyCn]
xx = Input Number ( 2 digits, 01-99 )
y
= Signal Present (1=signal, 0=no signal)
Cn = Card ID (n = slot # from 1 to max slots)
Example 1:
Check for a signal on Input 1 of the engine in
slot 5 by sending the command [SDI01C5]. If
there is a signal present on Input 1, the system
will return the following feedback:
[I01S1C05]
Example 2:
Check for a signal on all inputs of the engine in
slot 5 by sending the command [SDIC5]. In this
case, there is a signal on Input 1, but the rest
have no signals. The system will return the
following feedback:
[I01S1C05] [I02S0C05] [I03S0C05] [I04S0C05]
[I05S0C05] [I06S0C05] [I07S0C05] [I08S0C05]
… [I63S0C05] [I64S0C05]
22.
[SDO]
This command is used to detect if there is a
signal present on one output or all outputs. The
system will return feedback along the following:
Command Format, One Output
: [SDOmmCnUi]
Command Format, All Outputs:
[SDOCnUi]
mm = Output (2 digit # from 01 to 64)
Cn = Card ID (n = slot # from 1 to max slots)
Ui
= Unit ID (i = # from 0 to 9)
Feedback Format: [OxxSyCn]
xx = Input Number ( 2 digits, 01-99 )
y
= Signal Present (1=signal, 0=no signal)
Cn = Card ID (n = slot # from 1 to max slots)
Example 1:
Check for a signal on Output 1 of the engine in
slot 5 by sending the command [SDO01C5]. If a
signal present on Output 1, the following
feedback will be returned:
[O01S1C05]