![Altendorf F45 ProDrive Operating Manual Download Page 197](http://html1.mh-extra.com/html/altendorf/f45-prodrive/f45-prodrive_operating-manual_2910755197.webp)
Faults/problems/troubleshooting
197
0000010038-003- GB
Faults/problems/troubleshooting
Fault message
Cause
Troubleshooting
B000 - B063
Internal faults
Request a service technician to check the
function.
E01
Limit switch ES_MIN1 reached
E02
Limit switch ES_MIN2 reached
E03
Limit switch ES_MAX reached
E06
Fault, collision, fast shutdown
E07
Drive positioning fault
E08
Axis reference run error
Perform new reference run
E18
Fresh oil lubricator empty
Change cartridge
E21
Error during update:
File error on the USB stick
E22
Error during update:
File errors on the USB stick (vari-
ous)
E40
20VAC control voltage missing
Check fuse F9
E41
24VAC control voltage missing
Check fuse F8
E42
Scoring saw motor overheated
Allow motor to cool down.
E43
Main saw motor overheated
Allow motor to cool down.
E44
Sliding table limit switch
E45
Saw blade cover open
E46
Machine door open
E47
EMERGENCY STOP button 1
pressed
E48
EMERGENCY STOP button 2
pressed
E49
EMERGENCY STOP button 3
pressed
E51
Brake unit fault: Phase failure/rota-
tional direction
Check fusing in the factory and fuses F15 /
F16.
Summary of Contents for F45 ProDrive
Page 8: ...Identification 8 Identification 0000010038 003 GB EC prototype testing certificate...
Page 9: ...Identification 9 0000010038 003 GB Identification...
Page 10: ...Identification 10 Identification 0000010038 003 GB GS test certificate...
Page 11: ...Identification 11 0000010038 003 GB Identification...
Page 12: ...Identification 12 Identification 0000010038 003 GB DGUV Test Certificate...
Page 13: ...Identification 13 0000010038 003 GB Identification...
Page 14: ...Identification 14 Identification 0000010038 003 GB C US Certificate...