Operating
164
Operating
0000010038-003- GB
Basic setting of the display unit
The basic setting of the display unit is needed in order to adapt the measuring
system to the machine situation. Check and, if necessary, re-enter the basic
settings following each tool change. The basic setting can only be carried out
together with the tools used so it cannot be done at the factory.
•
Push the fence including the display unit to the right against the mechanical
stop and fix with a clamping screw.
•
Cut a test piece, measure the workpiece width with a vernier calliper and
enter the precise value as follows:
•
Press the F button, all digits of the display will light up after 3 seconds.
•
Hold the F button down.
•
The right-hand digit of the display starts flashing.
•
Pressing the + button increases the flashing digit by 1 each time. When the
maximum number value 9 is passed, the numbers start again with 0.
•
Pressing the - key reduces the flashing digit by 1 each time; when the
maximum numeric value (9) is passed, the numbers start again with 0.
•
Release the F key.
•
The dimension that has been set is saved as the basic setting.
•
The display unit is now ready for operation.
Switching the display unit from mm to inches or inches to mm
•
Hold the + button down for more than 3 seconds; the display shows inches
(or mm).
•
Release the + key; the display unit now shows the set dimension in inches
(or mm).
Summary of Contents for F45 ProDrive
Page 8: ...Identification 8 Identification 0000010038 003 GB EC prototype testing certificate...
Page 9: ...Identification 9 0000010038 003 GB Identification...
Page 10: ...Identification 10 Identification 0000010038 003 GB GS test certificate...
Page 11: ...Identification 11 0000010038 003 GB Identification...
Page 12: ...Identification 12 Identification 0000010038 003 GB DGUV Test Certificate...
Page 13: ...Identification 13 0000010038 003 GB Identification...
Page 14: ...Identification 14 Identification 0000010038 003 GB C US Certificate...