![Altech ATE-053DCIMX05 Technical & Service Manual Download Page 8](http://html1.mh-extra.com/html/altech/ate-053dcimx05/ate-053dcimx05_technical-and-service-manual_2910627008.webp)
Indoor Unit
C
ro
s
s
fl
o
w
f
a
n
E
v
a
p
o
ra
to
r
Liquid valve A
Liquid valve B
Gas valve B
Gas valve A
EXVA
EXVB
Axial flow fan
Condenser
Compressor
4-way
valve
Auxiliary
Capillary
Capillary A
Capillary B
Exhaust
temp. sensor
Indoor pipe out
temp. seneor A
Indoor pipe out
temp. seneor B
Filter A
Filter B
Outdoor Unit
Main
Capillary
Check
Valve
Coil temp.
sensor
4 Temperature Operation range
Indoor temperature
17
°C
Cooling mode
Outdoor temperature
50°C
Indoor temperature
<=30
Heating mode
Outdoor temperature
-15 24
Indoor temperature
10
Dry mode
Outdoor temperature
0°C 50°c
5. Indoor units combination
5.2 Indoor unit combination for ATE-053DCIM2X05
2QHXQLW
7ZRXQLW
5.4 Indoor unit combination for ATE-079DCIM3X05
2QHXQLW
7ZRXQLW
7KUHHXQLW
Summary of Contents for ATE-053DCIMX05
Page 6: ...c ATE 081DCIM4X05...
Page 9: ...5 6 Indoor unit combination ATE 081DCIM4X05 2QH XQLW 7ZR XQLW 7KUHH XQLW RXU XQLW...
Page 10: ...6 Wiring Diagram 6 1 Indoor unit TAILLE 021 026 035 053 6 3 Outdoor unit ATE 053DCI2X05...
Page 11: ...6 4 Outdoor unit ATE 079DCI3X05 6 6 Outdoor unit ATE 081DCI4X05...