![Altech ATE-053DCIMX05 Technical & Service Manual Download Page 17](http://html1.mh-extra.com/html/altech/ate-053dcimx05/ate-053dcimx05_technical-and-service-manual_2910627017.webp)
7.7 Cooling mode
7.7.1 Indoor fan keeps running, fan speed can be set in high/mid/low/ Auto:
7.7.2Auto fan at cooling mode: (T=Indoor Temp.-Setting Temp.)
Condition
Indoor fan speed
T<1.5
Low
1.5
<T<4
Mid.
Room temp. up
T>4
High
T> 3
High
1
<T<3
Mid.
Room temp. down
T<1
Low
7.7.3Anti-freezing control to indoor evaporator at cooling mode( T: evaporator temp. )
Evaporator Temp.
Compressor
T< 4
Off
T > 8
On
7.8 Dehumidifying mode
7.8.1the indoor fan is fixed in low speed
7.8.2Low room temperature protection:
When room temperature decreases to below 10
, indoor fan stop, when room
temperature restores to over 12
, indoor fan start.
7.8.3At dehumidifying mode, the anti-freezing function of the indoor heat exchanger is the
same as that of cooling mode.
7.9Heating mode
7.9.1Indoor Fan actions at heating mode
Indoor Fan can be set at HIGH/MID/LOW/AUTO by using a remote controller, but
Anti-cold wind function prevails.
Anti-cold wind control function at heating mode
Condition
T=
Indoor
exchanger
temp.
Indoor fan speed
T<34
Off
34
<T<37
Breeze
37
<T<44
Low speed
Indoor exchanger temp.
up
T> 44
Setting fan speed
T> 38
Setting fan speed
33
<T<38
Low speed
24
<T<33
Breeze
Indoor exchanger temp.
down
T<24
Off
7.9.2Auto wind at heating mode
Condition
T=Indoor
Temp.-Setting
Temp.
Indoor fan speed