8.2 Troubleshooting for indoor unit
Display
LED STATUS
E0
EEPROM error
E1
Communication error between indoor and outdoor unit
E2
Zero-crossing examination error
E3
Fan speed beyond control
E5
Outdoor units temp. sensor or connector of temp. sensor is defective
E6
Indoor units temp. sensor or connector of temp. sensor is defective
P0
Inverter module protection
P1
Outdoor voltage protection
P2
Compressor temp. protection
P3
Compressor current protection
8.3 LED error code display for outdoor unit
Display
LED STATUS
E0
EEPROM error
E1
#1 evaporator outlet
pipe temp. sensor or connector of pipe temp. sensor is defective
E2
#2 evaporator outlet
pipe temp. sensor or connector of pipe temp. sensor is defective
E3
#3 evaporator outlet
pipe temp. sensor or connector of pipe temp. sensor is defective
E6
#4 evaporator outlet
pipe temp. sensor or connector of pipe temp. sensor is defective
E4
Outdoor temp. sensor or connector of temp. sensor is defective
E5
Compressor voltage protection
E7
Communication error
between outdoor IC and DSP
P0
Compressor temp. protection
P1
High pressure protection (just for 27K and 36K 1x4 units.)
P2
Low pressure protection (just for 27K and 36K 1x4 units.)
P3
Compressor current protection
P4
Inverter module protection
P6
Condenser high-temperature protection
P7
Compressor driving protection