3 Refrigeration Cycle Diagram
3.1 Refrigeration circuit drawing of inverter quadplex type
3.2 Refrigeration circuit drawing of inverter trinary type
3.3 Refrigeration circuit drawing of inverter binary type
Liquid valve A
Gas valve C
EXV C
4-way
valve
Compressor
Condenser
Axial flow fan
EXV B
EXV A
Gas valve A
Gas valve B
Liquid valve C
Liquid valve B
Evaporator
Cross
flow fan
Indoor Unit
Capillary A
Capillary B
Capillary C
Filter A
Filter B
Filter C
Main
Capillary
Auxiliary
Capillary
Check
Valve
Exhaust
temp. sensor
Indoor pipe out
temp. seneor B
Indoor pipe out
temp. seneor A
Indoor pipe out
temp. seneor C
Outdoor Unit
Coil temp.
sensor