background image

 

Page 1

 

P012548-14 - Rev D 

                

CO2-PG14    CO2-FREE GAS GENERATOR 

OPERATIONS & MAINTENANCE 

 
 
 
 
 

 

 
 
 
 

TABLE OF CONTENTS 

 

SECTION 1 

General Information: 

Pg 2 

 

 

Serial Numbers 

 

 

Description of Operation 

SECTION 2 

Safety Instructions: 

Pg 3 

 

 

Installation Safety 

 

 

Operation Safety 

SECTION 3 

Specifications: 

Pg 3 

 

 

Flows, Connections, Dimensions, and Weights 

SECTION 4 

Installation 

Pg 4 

 

 

Parts Included 

 

 

Location 

 

 

Electrical Connections 

 

 

Piping and Connections 

 

 

Filters 

SECTION 5 

Start-Up 

Pg 4 

SECTION 6 

Maintenance 

Pg 4 

SECTION 7 

Replacement Parts 

Pg 5 

SECTION 8 

Troubleshooting Guide 

Pg 6 

SECTION 9 

Wiring Diagram 

Pg 7 

SECTION 10 

Warranty / Claims 

Pg 7 

 
 

 

PRINTED IN THE USA

 

Summary of Contents for CO2-PG14

Page 1: ...allation Safety Operation Safety SECTION 3 Specifications Pg 3 Flows Connections Dimensions and Weights SECTION 4 Installation Pg 4 Parts Included Location Electrical Connections Piping and Connection...

Page 2: ...this tower removes CO2 to less than 1 ppm and 99 9 of the water vapor from the air when operated at standard catalog conditions The dry CO2 free air leaving the top of the tower T1 is directed to the...

Page 3: ...de pressurize the unit before starting installation or maintenance procedures The CO2 PG14 is rated NEMA 1 2 2 OPERATION SAFETY DO NOT OPERATE THE PURGE GAS GENERATOR AT COMPRESSED AIR PRESSURES ABOVE...

Page 4: ...T IN AN ENVIRONMENT OF CORROSIVE CHEMICALS EXPLOSIVE GASES OR AREAS OF HIGH AMBIENT TEMPERATURE CONDITIONS 4 3 ELECTRICAL CONNECTIONS Before plugging in unit check the unit nameplate for electrical ch...

Page 5: ...ER DRYER IS DEPRESSURIZED BEFORE WORKING ON THE ADSORBER DRYER OR RELATED EQUIPMENT ENSURE THAT ALL PERSONNEL HAVE READ AND UNDERSTAND THE SAFETY AND OPERATION INSTRUCTIONS IN THIS MANUAL 6 1 PREVENTI...

Page 6: ...ee Sec 6 1 OUTLET FILTER REGULATOR WITH GAUGE 1 1 1 1 See Sec 6 1 OUTLET FILTER ELEMENT ONLY 1 1 1 1 See Sec 6 1 REGULATOR ONLY 1 1 1 1 50027 TIMER CYCLE 115 VAC 1 50029 TIMER CYCLE 220 VAC 1 51408 TI...

Page 7: ...ed outlet flow Reduce air usage downstream A4 Dirty or obstructed inlet air filter Check inlet coalescing filter element Replace inlet filter element A5 Purge orifice plugged Check purge air flow with...

Page 8: ...t air passages and piping for blockages Clear restrictions C PROBLEM EXCESSIVE PURGE POSSIBLE CAUSE CHECK CORRECTIVE ACTION C1 Inlet valve or outlet shuttle not shifting Check for damage or contaminat...

Page 9: ...be repaired replaced or refunded at Altec AIR s option free of charge provided that Altec AIR is notified within the above stated warranty period All returns of defective parts equipment must have pr...