18231
ThermOne trim kit /
garniture pour ThermOne
alt-aqua.com
To Service The Cartridge
If necessary, shut off the main water supply, then
remove all the components from (1) to (5). Fig.5.
Afterwards, shut off the 2 check valves (8) by turning
them clockwise with a screwdriver. Unscrew the
cartridge holder (6) and remove the cartridge (7)
(Fig. 5).
To clean the cartridge, you may need to soak it in a
vinegar and water solution to remove lime build-up. If
replacement is necessary, insert the new cartridge and
screw the cartridge holder (6) back on.
DO NOT OVERTIGHTEN.
To reinstall the components, just reverse the above
steps. Reinstall the plate back onto the finished wall.
Entretien de la cartouche
Si nécessaire, fermer l'alimentation d'eau principale et
démonter toutes les composantes de (1) à (5). Fig.5.
Ensuite, fermer les deux valves d'arrêt (8) en les
tournant dans le sens horaire avec un tournevis. Dé-
visser le manchon de valve (6) et enlever la cartouche
(7). Fig. 5.
Pour nettoyer la cartouche, l'imbiber d'une solution
d'eau et de vinaigre. Si un remplacement s'avère
nécessaire,, insérer la nouvelle cartouche et revisser le
manchon de valve (6).
NE PAS TROP SERRER.
Pour réassembler les composants, inverser les
étapes ci-haut. Réinstaller la plaque contre le mur de
finition.
7
5
6
4
3
1
2
8
Fig.5
MAINTENANCE
ENTRETIEN