Chapter 13
– RPV Manager
RPV311
RPV311-TM-EN-6
247
2. To set the update interval change the field "Auto Refresh Interval " on the Configuration>Polling
menu;
3. To activate or deactivate the Auto Refresh, access the Polling menu and choose between Manual or
Auto options;
4. To ensure that the software starts with the Auto Refresh option active, check the box "Auto Polling
on Init" on the Configuration>Polling menu;
The refresh action also happens during the:
Start of application execution;
Change in list of substations;
Change in the equipment list.
After communication with the equipment, the software checks if any information was changed and updates
the information as follows:
Interface: System Monitor equipment tree tab and equipment lists in the other tabs;
Database;
Information of the Transmission Line configurations for each device;
Name of the directory where the new records will be downloaded.
3.4.2
POLLING
The polling routine is responsible for performing the automatic download of records from each equipment.
Configure the Auto Polling as follows:
1. For each equipment if you want to have Auto Polling functionality, "Enable Auto COMTRADE
Download " should be enabled.
2. To set the update interval, the field "Auto Polling Interval" must be changed in the Polling
configuration screen.
3. To activate or deactivate the Auto Polling, access the menu Polling Auto, to activate, and Polling >
Manual, to disable.
4. To ensure that the software starts with the Auto option active Polling, select the field "Auto Polling on
Init" on the Polling configuration screen
5. COMTRADES records will only be downloaded that are younger than the period entered in the field
“Polling COMTRADE Acts ", in Polling configuration screen,
6. Only the types of COMTRADE records configured through the fields "Retrieve ..." in the Polling
configuration screen of will be downloaded.
7. To run the fault location algorithm automatically after downloading a COMTRADE record, select the
field "Automatic Fault Location", in Polling configuration screen.
8. Once everything is configured, the records will be downloaded to the directory "COMTRADE
Directory "/Records.
Summary of Contents for Reason RPV311
Page 2: ......
Page 15: ...INTRODUCTION CHAPTER 1...
Page 34: ...SAFETY INFORMATION CHAPTER 2...
Page 45: ...HARDWARE DESIGN CHAPTER 3...
Page 56: ......
Page 57: ...CONFIGURATION CHAPTER 4...
Page 75: ...RPV311 Chapter 4 Configuration RPV311 TM EN 6 75 Figure 21 Email Fax configuration...
Page 77: ...RPV311 Chapter 4 Configuration RPV311 TM EN 6 77 Figure 22 Adding and editing voltage circuits...
Page 117: ...OPERATION CHAPTER 5...
Page 121: ...RPV311 Chapter 5 Operation RPV311 TM EN 6 121 Figure 46 Status monitoring sequence...
Page 123: ...RPV311 Chapter 5 Operation RPV311 TM EN 6 123 Figure 47 Monitoring sequence...
Page 128: ...Chapter 5 Operation RPV311 128 RPV311 TM EN 6 Figure 50 Equipment settings monitoring sequence...
Page 155: ...RECORDS CHAPTER 6...
Page 172: ......
Page 173: ...TW FAULT LOCATOR CHAPTER 7...
Page 183: ...PMU CHAPTER 8...
Page 189: ...MODBUS CHAPTER 9...
Page 193: ...DNP3 CHAPTER 10...
Page 196: ......
Page 197: ...GOOSE MESSAGE DETECTION CHAPTER 11...
Page 200: ......
Page 201: ...SOFTWARE RPV TOOLS CHAPTER 12...
Page 228: ......
Page 229: ...SOFTWARE RPV MANAGER CHAPTER 13...
Page 249: ...COMMUNICATIONS CHAPTER 14...
Page 261: ...INSTALLATION CHAPTER 15...
Page 295: ...Chapter 15 Installation RPV311 RPV311 TM EN 6 295 Figure 138 RA331 RA332 and RA333 dimensions...
Page 299: ...MAINTENANCE AND TROUBLESHOOTING CHAPTER 16...
Page 310: ...TECHNICAL SPECIFICATIONS CHAPTER 17...
Page 331: ...RPV311 Chapter 17 Wiring Diagrams WIRING DIAGRAMS CHAPTER 18...
Page 340: ...APPENDIX A...