6
018-354-B0-001, Rev. A (05/2018)
• The Gateway contains hazardous voltage. Only qualified personnel should service the Gateway.
WARNING! ELECTRICAL HAZARD
• CAUTION: FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH
SAME TYPE AND RATING OF FUSE:
• F2 2AG, Slo-Blo® Fuse Littlefuse 229/230 Series Type 0229 007. Rated 125V, 7A or equivalent.
WARNING! ELECTRICAL & FIRE HAZARD
• Only qualified personnel should service the Gateway
• Verify the voltage requirements of the equipment to be protected (load), the AC input voltage to the
Gateway (line) and the output voltage of the system prior to installation.
• When connecting the load, DO NOT exceed the output rating of the Gateway.
CAUTION!
AlphaGateway SMG Safety and Compliance Notes
Safety Precautions
Grounding and Earth Connection Notes
In order to provide a ready, reliable source of power, it is necessary to connect the Gateway to an effective grounding
and earthing system. This not only provides for the safety of the service personnel responsible for its operation and
maintenance, but also facilitates the proper operation and protection of the equipment within the network. Such a
grounding system provides protection with respect to operator safety, system communication and equipment protection.
Lightning strikes, grid switching or other aberrations on the power line and/or communications cable have the potential
to cause high-energy transients that can damage the powering or communications systems. The most viable method
available to protect the system from damage is to divert these unwanted high-energy transients along a low-impedance
path to earth. A low-impedance path to earth prevents these currents from reaching high voltage levels and posing a
threat to equipment.
Observe the safety information contained in the technical manuals for the various system components
(Gateways, Antennas, Power Passing Taps, Cables, and Connectors) as well as local codes for servicing
electrical systems and working at height.
WARNING! GENERAL HAZARD
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device
may not cause harmful interference, and (2) this device must accept any interference received, including interference that
may cause undesired operation.
This product has been inspected by regulatory for use as described in the manual. If your intended use is different, it
is your responsibility to ensure your combination conforms to your local regulatory requirements and the Gateway and
components remains within its environmental specifications.
ATTENTION:
Contains FCC ID: 2ALEPT0004564
FCC Compliance