5.0 LoRaWAN Operation, Continued
5.3 Alarm Reporting
Simplified Alarm Reporting
It is preferred to reduce the number of alarms in such a way that, for each unique alarm, there is a specific action to be
taken by the operator. Within each reported alarm, there can be additional descriptive text strings that can be used to
debug the specific fault condition. The list of LoRa gateway alarms is shown in Table 5-2.
Table 5-2, Alarms
Alarms
Alarm Description
Severity
Fault IDs linked to
this alarm
Action to be taken
Associated LED
state
Gateway shutdown
Critical
0x01
0x02
2
- Reset the gateway.
- Execute BIST.
- Check software versions and
upgrade if required
- If condition does not clear,
replace the gateway
Solid RED
Gateway Interface Alarm
Major
0x03
0x04
0x07
- Check the gateway interfaces
Blinking RED
Gateway Performance
Degradation
Major
0x05
- Check environmental conditions
at the gateway site
No change
Gateway high temperature
shutdown
Critical
0x06
- Check environmental conditions
at the gateway site
Solid RED
Status Update
Minor
- Review periodic BIST report
No change
2
Some radio operational faults have critical severity – others have major severity