3.8 BOILER SCHEMATIC
1
Gas isolation valve
2
Cold mains isolation valve
3
Gas valve
4
DHW flow switch
5
Gas injector
6
Flow regulator
7
DHW temperature sensor
8
Condensate trap
9
3 bar safety valve
10 Expansion vessel
11 Venturi positive pressure point (+)
Fig. 3.4
12 Venturi
13 Primary flow temperature sensor
14 Ignition/sensing electrode
15 Air supply pipe
16 Flue temperature sensor
17 Flue test point (pressure point +)
18 Air test point (pressure point -)
19 Burner
20 Primary return sensor
21 Fan
22 Automatic air vent
23 Boiler pump
24 Primary pressure switch
25 DHW heat exchanger
26 Diverter valve
27 By-pass
28 Drain point
29 Safety valve indicator
30 Heating return isolation valve
31 Heating flow isolation valve
Alpha Evoke 28 and 33 - Technical Data
Gas
Condensate discharge
and expansion relief
Primary
Heating
return
Primary
Heating flow
Domestic
hot water
outlet
Cold mains
water inlet
1
2
3
4
5
6
7
8
9
10
31
30
29
28
27
26
25
24
23
22
21
20
19
18
11
12
13
14
15
16
17