Alpha Evoke 28 and 33 - Energy Classification
12 ENERGY CLASSIFICATION
The values in the following tables refer to the maximum heating output.
Model(s):
Evoke 28
Condensing boiler:
YES
Low-temperature boiler:
NO
B1 boiler:
NO
Cogeneration space heater:
NO
Equipped with a supplementary heater:
NO
Combination heater:
YES
Item
Symbol
Value
Unit
Item
Symbol
Value
Unit
Rated heat output
P
n
24
kW
Seasonal space heating energy
efficiency
η
s
93
%
For boiler space heaters and boiler combination heaters: useful
heat output
For boiler space heaters and boiler combination heaters: Useful
efficiency
At rated heat output and high
temperature regime (*)
P
4
24.0
kW
At rated heat output and high
temperature regime (*)
η
4
88.1
%
At 30% of rated heat output and low
temperature regime (**)
P
1
8.0
kW
At 30% of rated heat output and low
temperature regime (**)
η
1
97.6
%
Auxiliary electricity consumption
Other items
At full load
el
max
0.010
kW
Standby heat loss
P
stby
0.057
kW
At part load
el
min
0.005
kW
Ignition burner power consumption
P
ign
0.000
kW
In standby mode
P
SB
0.002
kW
Emissions of nitrogen oxides
NO
X
35
mg /
kWh
For combination heaters:
Declared load profile
XL
Water heating energy efficiency
η
WH
87
%
Daily electricity consumption
Q
elec
0.122
kWh
Daily fuel consumption
Q
fuel
22.406
kWh
Contact details
Alpha Therm Ltd., Nepicar House, Wrotham Heath, Kent. TN15 7RS
(*) High temperature regime means 60°C return temperature at heater inlet and 80°C feed temperature at heater outlet.
(**) Low temperature means for condensing boilers 30°C, for low-temperature boilers 37°C and for other heaters 50°C return temperature.
Model(s):
Evoke 33
Condensing boiler:
YES
Low-temperature boiler:
NO
B1 boiler:
NO
Cogeneration space heater:
NO
Equipped with a supplementary heater:
NO
Combination heater:
YES
Item
Symbol
Value
Unit
Item
Symbol
Value
Unit
Rated heat output
P
n
28
kW
Seasonal space heating energy
efficiency
η
s
93
%
For boiler space heaters and boiler combination heaters: useful
heat output
For boiler space heaters and boiler combination heaters: Useful
efficiency
At rated heat output and high
temperature regime (*)
P
4
28.0
kW
At rated heat output and high
temperature regime (*)
η
4
87.9
%
At 30% of rated heat output and low
temperature regime (**)
P
1
9.3
kW
At 30% of rated heat output and low
temperature regime (**)
η
1
97.6
%
Auxiliary electricity consumption
Other items
At full load
el
max
0.012
kW
Standby heat loss
P
stby
0.057
kW
At part load
el
min
0.006
kW
Ignition burner power consumption
P
ign
0.000
kW
In standby mode
P
SB
0.002
kW
Emissions of nitrogen oxides
NO
X
30
mg /
kWh
For combination heaters:
Declared load profile
XL
Water heating energy efficiency
η
WH
87
%
Daily electricity consumption
Q
elec
0.131
kWh
Daily fuel consumption
Q
fuel
22.362
kWh
Contact details
Alpha Therm Ltd., Nepicar House, Wrotham Heath, Kent. TN15 7RS
(*) High temperature regime means 60°C return temperature at heater inlet and 80°C feed temperature at heater outlet.
(**) Low temperature means for condensing boilers 30°C, for low-temperature boilers 37°C and for other heaters 50°C return temperature.
12.1 TECHNICAL PARAMETERS FOR MIXED BOILERS (IN COMPLIANCE WITH REGULATION 811/2013)