APL48-50LFP liFePO
4
Battery Operation Manual
17
Annex 2
–
Instructions for ADD Dialing
ADD is applicable to modules connected in parallel. ADD consists of four binary bits, and
maximum quantity of batteries connected in parallel is 64pcs (2^6). BMS only identify ADD
dialing one time after reset, so reset BMS as change ADD dialing.
Annexed Table 2.1
–
Instruction for Addresses of Communication
Instructions for ADD Dialing
Module No.
Binary Code
Remarks
1
2
3
4
5
6
OFF
OFF
OFF
OFF
OFF
OFF
PACK 1
000000
Master PACK, supports
RS232
ON
OFF
OFF
OFF
OFF
OFF
PACK 2
000001
Slave PACK
OFF
ON
OFF
OFF
OFF
OFF
PACK 3
000010
Slave PACK
ON
ON
OFF
OFF
OFF
OFF
PACK 4
000011
Slave PACK
OFF
ON
OFF
OFF
OFF
OFF
PACK 5
000100
Slave PACK
ON
OFF
ON
OFF
OFF
OFF
PACK 6
000101
Slave PACK
OFF
ON
ON
OFF
OFF
OFF
PACK 7
000110
Slave PACK
ON
ON
ON
OFF
OFF
OFF
PACK 8
000111
Slave PACK
OFF
OFF
OFF
ON
OFF
OFF
PACK 9
001000
Slave PACK
ON
OFF
OFF
ON
OFF
OFF
PACK 10
001001
Slave PACK
OFF
ON
OFF
ON
OFF
OFF
PACK 11
001010
Slave PACK
ON
ON
OFF
ON
OFF
OFF
PACK 12
001011
Slave PACK
OFF
OFF
ON
ON
OFF
OFF
PACK 13
001100
Slave PACK
ON
OFF
ON
ON
OFF
OFF
PACK 14
001101
Slave PACK
OFF
ON
ON
ON
OFF
OFF
PACK 15
001110
Slave PACK
ON
ON
ON
ON
OFF
OFF
PACK 16
001111
Slave PACK
OFF
OFF
OFF
OFF
ON
OFF
PACK 17
010000
Slave PACK
ON
OFF
OFF
OFF
ON
OFF
PACK 18
010001
Slave PACK
OFF
ON
OFF
OFF
ON
OFF
PACK 19
010010
Slave PACK
ON
ON
OFF
OFF
ON
OFF
PACK 20
010011
Slave PACK
OFF
ON
OFF
OFF
ON
OFF
PACK 21
010100
Slave PACK
ON
OFF
ON
OFF
ON
OFF
PACK 22
010101
Slave PACK
OFF
ON
ON
OFF
ON
OFF
PACK 23
010110
Slave PACK
ON
ON
ON
OFF
ON
OFF
PACK 24
010111
Slave PACK
OFF
OFF
OFF
ON
ON
OFF
PACK 25
011000
Slave PACK
ON
OFF
OFF
ON
ON
OFF
PACK 26
011001
Slave PACK
OFF
ON
OFF
ON
ON
OFF
PACK 27
011010
Slave PACK
ON
ON
OFF
ON
ON
OFF
PACK 28
011011
Slave PACK
OFF
OFF
ON
ON
ON
OFF
PACK 29
011100
Slave PACK
ON
OFF
ON
ON
ON
OFF
PACK 30
011101
Slave PACK
OFF
ON
ON
ON
ON
OFF
PACK 31
011110
Slave PACK
ON
ON
ON
ON
ON
OFF
PACK 32
011111
Slave PACK