Alpha Technologies PRIma Gate User Manual Download Page 5

PRIma Gate 

5

GSM  Gateway 

is  a compact  highly  sophisticated  system.  It  supports  full  remote 

supervision and configuration via an IP network or USB port. The system has been designed 
and works with a lot of highly sophisticated functions, which make it fully client-oriented and 
highly  reliable in cooperation with both GSM networks and ISDN. Configuration alterations 
can be made without resetting, i.e. under full operation.  

 

Basic general features

 

• 

Connection to the exchange through ISDN E1 interface with DSS1 signaling or QSIG 

• 

4x GSM channels, upgradeable to 32 

• 

4x PRI ISDN interface 

• 

The outgoing calls from PBX extensions are route via the GSM modules in the 
Gateway 

• 

Direct Inward System Access  (DISA) 

• 

Mobility extension 

• 

Alarm indication 

• 

Call Detail Record (CDR) 

• 

SMS server 

• 

Call back 

• 

Smart Call back 

• 

Advice of charge (AOC) 

• 

Channel assotiation 1:1with GSM modules 

• 

Least Cost Routing for outgoing GSM calls (LCR) - helps your company to reduce the 
phone cost 

• 

Incoming and outgoing calls managed by groups. (SIM card groups) 

• 

SIM card protection using PIN 

• 

Advance credit management (minutes credit) 

• 

You can manage the Gateway using a Configuration SW running under the 
Windows XP, Vista, Windows 7 via USB or LAN port  

• 

Diagnostics of ISDN lines, ISDN lines Credit, GSM Modules Status and Credit  

• 

Status of modules with signal quality  

• 

Statistics  

Summary of Contents for PRIma Gate

Page 1: ...USER Manual GSM Gateway PRIma Gate...

Page 2: ...Quit 10 2 View 10 2 1 Toolbar 10 2 2 Status 10 3 Connection 10 4 Options 10 4 1 Interface 11 4 2 Modem Setting 11 4 3 Language 11 4 4 Password 11 4 5 Date Time 12 5 Service 12 5 1 System Information 1...

Page 3: ...M 32 6 6 Mobility Extension 33 7 Diagnostics 34 7 1 ISDN lines 34 7 2 E1 lines credit 34 7 3 GSM modules 35 7 4 GSM modules credit 35 7 5 Statistic In Use 36 7 6 GSM Modules Statistics 36 Appendix 37...

Page 4: ...stalling this product check whether the delivery is complete and read this manual thoroughly The manufacturer cannot be held responsible for any damages that occurred due to incorrect use of this prod...

Page 5: ...x PRI ISDN interface The outgoing calls from PBX extensions are route via the GSM modules in the Gateway Direct Inward System Access DISA Mobility extension Alarm indication Call Detail Record CDR SMS...

Page 6: ...ted to E1 A port Ports E1 C and E1 D are in present time reserved for future applications Each of these interfaces can be configured as TERMINAL or as NETWORK independently and each of these interface...

Page 7: ...eiving connector pair can be made either automatically according NT or TE configuration setting or manually according user setting For this selection is not need to switch any jumpers on CPU board all...

Page 8: ...des Possible statuses of indication LED diodes Possible statuses of indication LED diodes Possible statuses of indication LED diodes LED Color Description NONE Module is Not configured GREEN LIGHT Con...

Page 9: ...In this pane you can create the new configuration and load default setting in the tree and set or change it 1 2 Open Program opens a file from a folder selected by you 1 3 Save Program saves a file of...

Page 10: ...am 2 2 Status Display or hide status line on the bottom of pane 3 Connection Section Connection allows you to connect or disconnect COM port or Modem If you choose to connect by modem the window will...

Page 11: ...COM port which makes communication gateway with your modem Initialization command Type AT command according to modem The number 60 means how long lasts the connection without exchange of messages Dial...

Page 12: ...e gateway and allows display System Monitor available only if the Gateway is connected 5 1 System Information This item displays System information 5 2 Reset System restarts the gateway and initialize...

Page 13: ...nection is unstable it is possible failure of update firmware 5 4 Module reset You can choose the GSM module to reset it 5 5 Update Annoucements System writes Annoucements file LMF into Gateway 5 6 Sy...

Page 14: ...ameters as System ISDN GSM LCR Least Cost Routing CLIP from GSM and numbers for Mobility Extension 6 1 System This pane allows you to assign General parameters to set network parameters Network parame...

Page 15: ...u to park a call until it can be transferred or managed You can dial the number of other user and the hold user is listening music When other user answers the call or is ringing you can transfer this...

Page 16: ...with some GSM module Description of Alarm Message is in appendix GSM numbers for SMS alarm indication In this section you can set max 5 numbers for SMS message If this numbers aren t filled alarm mess...

Page 17: ...slog protocol If this address isn t filled CDR messages are not sent Timeout minutes You can set period for transmission of CDR The value is from 1 to 65534 minutes Store CDR for You can choose storin...

Page 18: ...ately GSM modules SMS server When using the SMS Mail application the GSM gate allow transmission or receipt of SMS messages 6 2 ISDN This pane contains setting of ISDN line You can set Common properti...

Page 19: ...ut prefixes 0 and 00 in GSM CLIP 00420 420 Default this function is not use Country prefix for change GSM CLIP from international to national format You can set the national format For example You typ...

Page 20: ...Number of SIM cards with poor signal 0 32 Default 0 this function is not use Parameter for poor signal definition 113 dBm 51dBm You can set the level of poor signal only odd numbered ISDN cause if GSM...

Page 21: ...py channels from channel 1 to 32 Downwards channel selection B side Gateway will occupy channels from channel 32 to 1 Cyclic channel selection Gateway will occupy channels from last engaged 1 1 channe...

Page 22: ...the carrier Example 1 If the call is charged per second set both parameters to 1 Example 2 If you are charged immediately after answering a call for the whole first minute and then second by second s...

Page 23: ...on clock accordance order in table Order of synchronization You can added or reduce any of E1 links and move up or down their sequence First line in the pane Order of synchronization has the highest p...

Page 24: ...ment GSM modules to GSM group and allows setting SIM card Configuration Disable You can define unused GSM card if you tick off Disable Echo cancelation You can choose ON OFF echo Roaming You can permi...

Page 25: ...GSM Range of volume is from 6 dB to 12 dB Assignment to GSM groups It is possible to set each module 1 32 and assign its GSM Incoming Groups its GSM Outgoing groups and second outgoing group or no de...

Page 26: ...count are used for account of the real length of the call from the view of GSM operator Example 1 If the call is charged per second set both parameters to 1 Example 2 If you are charged immediately a...

Page 27: ...back and receive You can activate callback see section List of GSM numbers in GSM incoming group which can use callback function other calls will be routed to ISDN interface Callback and reject You ca...

Page 28: ...horized DISA and receive during working hours Other calls which CLIP is not in list of GSM number or time is out of the working hours are routed to the extension entered in table extensions Waiting fo...

Page 29: ...xtensions in order if the parameter Waiting for DISA 0 60 seconds is setting in 0 or number of called digits is less then Minimal extension length Maximal count of this extension is 5 extensions If yo...

Page 30: ...s about modules in each group 6 4 LCR Least Cost Routing A fully intelligent LCR function is the basic tool allowing to route outgoing ISDN calls to GSM networks or ISDN network by the called number p...

Page 31: ...list by by pressing button Add Number You can define digits of this routing Number modification You can define length of cut digits and digits for inserting before called number Outgoing targets list...

Page 32: ...ing profile 1 254 setting in CLIP Parameters are the same as the Default routing profile 6 5 CLIP from GSM You can add change or delete GSM numbers to List of GSM numbers List of GSM numbers This is l...

Page 33: ...ringing all entered numbers in compliance with condition Numbers can be PBX extensions PSTN or GSM numbers First user which picks up phone is connected and the others stop ringing You can set when num...

Page 34: ...displays status of lines from E1 to E4 Free space signalizes OK parameter of actual line Red indicator signalizes ERROR Blue indicator signalizes WARNING 7 2 E1 lines credit There is information about...

Page 35: ...dix Double clicking on Module displays other GSM Module Information as Module Type IMEI IMSI Network ID 7 4 GSM modules credit There is information about each GSM module and its credit Each module has...

Page 36: ...PRIma Gate 36 7 5 Statistic In Use This pane displays how many modules is current in use last 13 minutes 7 6 GSM Modules Statistics This pane displays how many modules were in use last 24 hours...

Page 37: ...S 300 102 Example CDR110314_01 CSV 1 2 3 4 5 6 7 8 9 Date Time Call Type Caller Id Called Number Call Length Input Port Output Port Cause 14 3 2011 16 39 38 Answered Call 265 50 0 00 04 PBX 31 GSM 3 1...

Page 38: ...ll 10 Incoming Call blue Active call 11 ISDN Disconnect dark green ISDN disconnected 12 GSM Disconnect dark green GSM disconnected 13 SMS comunication magenta Error states module is out of work Descri...

Page 39: ...scription of error Name Gateway Identification setting in General Number of Module 01 32 Description of error see table below Example PrimaGate 01 No Network Description of Alarm GENERAL Note No Board...

Page 40: ...ror 16 SIM blocked CME Error 262 CME Error 999 General CME ERROR Codes GSM 07 07 Description of Alarm PCM ERROR Note Loss of Signal LOS Alarm Indication Signal AIS Loss of Frame Alignment LFA Receive...

Page 41: ...phase 2 2 Transmission output per channel 900MHz 2W 1800MHz 1W VF connector RF connector 50 GSM boards PRI Interface s Interface 1 4 x ISDN PRI Signaling Q 931 EDSS1 Q SIG Type NT or TE NT TE TEI num...

Reviews: