3.4 Protection
Items
Description
Remark
Cell/PACK high-voltage
When charging, the system will stop charging if any
cell or PACK voltage reach the protection value and
it will be released only when both Pack and cell
voltage back to the release voltage range.
Automatc
recovery
Cell/PACK low-voltage
When discharging, it will reach over-discharged
protection of battery to stop discharging if any cell or
PACK voltage is under the protection value and it
will be released only when all the cell voltage back to
the release voltage range.
Can Automatic
recovery. Please
charge timely,
otherwise it may be
in Low-power mode
to be over-
discharged.
High temperature
When the battery cell, MOS, and ambient
temperature are higher than the set value, the
system will stop charging or discharging
according to the category, or disconnect at the
same time.
Automatc
recovery
Low temperature
When the battery cell, MOS, and ambient
temperature are higher than the set value, the
system will stop charging or discharging
according to the category, or disconnect at the
same time.
Automatc
recovery
Charge overcurrent
When the charging current is higher than the
protection value, the system will stop charging. And
it will release from the protection when the system
delays after rated time. Please note the maximum
charging current provided by power supply should
not exceed the protection value when using the
battery.
Automatic recovery.
If locked after three
consecutive times,
manual intervention
is required.
Overload
When the discharging current is higher than the
protection value, the system will stop discharging.
And it will release from the protection when the
system delays after rated time. Please note the
maximum discharging current requested by the load
should not exceed the protection value when
using the battery.
Automatic recovery.
If locked after three
consecutive times,
manual intervention
is required.