19
Subject to technical amendments without notice | 83050700gUK – Translation of the original operating manual | ait-deutschland GmbH
Push down the hooked in control panel, until it
latches into place.
Push the control cable of the heating and heat
pump controller into the
right‑hand
socket on the
underside of the control panel.
NOTE
A connection to a computer or a network can
be made via the left socket at the bottom of
the control panel, thereby allowing the heat-
ing and heat pump controller to be controlled
remotely from there. This requires a shielded
network cable (category 6) to be laid through
the unit during the electrical connection work.
Operating manual for the heating and heat
pump controller, “Qualified technician” version,
“Web server” section
If this network cable is available, insert the
network cable's RJ-45 connector into the left
socket of the control panel.
NOTE
The network cable can be exchanged at any
time. In order to be able to connect it, the
screen must first be removed.
27 Installation and removal
of the screen
27.1 Installing the screen
NOTE
The masking plate is provided in the as deliv-
ered unit so that the control panel is inserted
in the upper recesses of the front panel.
If the control panel has been inserted in the
lower recesses of the front panel, you must
first remove the masking plate's dummy cover
and then reinsert it above the logo.
Screen at time of delivery:
1 Recess for control panel
2 Logo
3 Dummy cover
First, insert the masking plate
below
in the slots
provided in the front panel.
Then, beginning on one side, latch the
lugs on the
masking plate
from the bottom up
into the slots
provided in the front panel.