Malfunctions
In the event of a malfunction, you can detect the cause of
the malfunction via the diagnostic program of the heating
and heat pump regulator.
Operating manual for the heating and heat pump
regulator.
CAUTION!
Service and repair work on the components
of the unit may be performed only by
customer service personnel authorized by
the manufacturer.
Overview “Customer service”.
Note that no malfunction is displayed if the safety
temperature limiter on the electric heating element has
been triggered (depending on model).
“Commissioning”, “Safety temperature limiter”
section.
Scope of delivery
Example of scope of delivery:
Compact unit with
• completely hermetically enclosed
compressor, all safety-related components
for monitoring of the cooling circuit
• electric switch cabinet with power
contactor and soft starter
• sensors mounted in the unit for
monitoring hot gas-, heating water forward
flow and return flow temperatures
• hose for condensate discharge
(connected to heat pump side)
• drainage hose for safety valve
(connected to heat pump side)
• Outdoor sensor
• Changeover valve domestic hot water
• with variant models that have
heat quanity recording:
with energy efficient circulating pumps,
heat quantity recording and Ventilation
circuit board (LWC 60 and LWC 80) or
Comfort board (LWC 100 and LWC 120)
For the scope of delivery, see Overview
“Technical data / scope of delivery”.
Inspect delivery for outwardly visible signs of
damage.
Check to make sure that delivery is complete…
Any defects or incorrect deliveries must be claimed
immediately.