13
Subject to change without notice | 83059000gUK – Translation of the original operating manual | ait-deutschland GmbH
NOTE
The sound emissions of the heat pumps must
be taken into account in the respective instal-
lation plans for air/water heat pumps. The re-
spective regional regulations must be com-
plied with.
Aligning the unit
1. Align the compact module horizontally and stably
in the installation site using the height-adjustable
feet and a size 13 spanner. Adjustment range:
20 mm. Then fasten with the size 17 lock nuts.
2. Place the heat pump module on the compact
module.
If the fan module has been removed this must be
reinstalled on the evaporator module. Attach the 4
screws (1) and re-establish the two plug-in connections
of the load and bus cables.
Do not change the adjustable feet of the heat pump
module as otherwise the housing walls will no longer
fit!
3. Remove the two lashing straps.
4. Open the strap tensioner and turn the hook on the
base plate by 90°.
90°
5. Attach the swelling tape to the louvre grille and
blind cover by applying it around the edges and
then sticking it in place.
Heat pump installation instructions
6. Remove the two styrofoam crosspieces.
7. Install the blind cover and the louvre grille.
807xxx
Attach the louvre grille to the air outlet side (right
or left)! The blind cover on the opposite side.
8.
Attach rear wall and screw firmly into place.
Heat pump installation instructions