Alpha-InnoTec LW 161H/V Operating Manual Download Page 39

39

Subject to change without notice  |  83061600bUK  |  ait-deutschland GmbH

LW161H-V

-

a

-F11

-X10

-A2

-Q6

-F12

-X10

-F10

-F13

-X10

HUP/ZUP

K13

-X10

-A5

EVU

Legend:

Equipement

A1

A2

A3

A5

EVU

F10

F11

F12

F13

K13

Terminals

OUT1

OUT2

OUT3

OUT4

OUT5

OUT6

OUT7

OUT8

NTC2

NTC3

NTC4

NTC5

NTC8

IN3

IN4

IN5

X10

Q

6

HUP

BUP

ZUP

acronym

ZW2

ZIP/BLP

FP1

MZ1/MIS

MA1/MIS

ZUP

BUP

HUP

TA

TBW

TB1

TRLext.

TRL

EVU1

EVU2

STB FBH

ZW2

MIS

-X3-1

FP1

ZIP/BLP

UK

Function

Controller board; Attention: I-max = 6,3A/230VAC

Heat pump

Sub-distribution unit internal installation

Hot water or buffer storage tank

Energy supplier 

Three pole miniature circuit-breaker of compressor to IEC 60947

-2

Cut out controller unit

Cut out auxiliary heating

Cut out auxiliary heating 2

Contactor electric heating element hot water or buffer tank

Control signal of additional heat generator 2 (alternative is g

eneral malfunction)

circulation pump / Domestic Water charge pump

Pump for mixing circuit 1

Charge/discharge/mixer 1 closed

Charge/discharge/mixer 1 open

Auxiliary circulation pump

Accessories: Process water sensor/thermostat

Heating circuit circulating pump

External sensor

Hot water gauge/thermostat

Sensor mixing circuit 1

External return sensor

Return sensor

Energy supplier contact; closed on release; bridge if no blocki

ng interval

Energy supplier contact; closed on release; bridge if no blocki

ng interval

Safety temperature limiter for underfloor heating, bridge if no

t available

terminal in switch box heat pump; L/N/PE distribution for exter

nal 230V devices

Contactor for auxiliary heating

831229a

-X3-2

-X4

-A1

-X5-1

-X5-2

1

23

45

678

12

8

A

B

C

D

E

F

A

B

C

D

E

F

Blatt

Bl.

1

1

3

45

67

AIT

831229

Stromlaufplan

ait-deutschland GmbH

PEP012/2017

ÄM029/2018

30.01.2018

24.07.2018

AP

AP

1~N/PE/230V/50Hz

1N

3

PE

2/T1
4/T2
6/T3

3~N/PE/400V/50Hz

5

L1
L1

3~N/PE/400V/50Hz

5

L2
L3

N

PE

3~N/PE/400V/50Hz

5

1
2
3
4

A1

A2

L
L

N

2

N

PE
PE

A1

A2

ZW2

OUT8
OUT7
OUT6
OUT5
OUT4
OUT3
OUT2
OUT1

N
N

L

IN1
IN2
IN3
IN4
IN5

L1
L1
L1

NTC1

GND1

NTC2

TA

GND2

NTC3

TBW

GND3

NTC4

TB1

GND4

NTC5

TRL ext.

GND5

NTC6

GND6

NTC7

GND7

NTC8

TRL

GND8

NTC9

GND9

-A3

Änderung

Datum

Datum

Bearbeiter

Geprüft

Norm

Name

30.01.2018

Pfleger

R.

blue

brown

black

M

Terminal diagram

LW 161H(L)/V

Summary of Contents for LW 161H/V

Page 1: ...UK 83061600bUK Air Water Heat Pumps Indoor installation Operating Manual LW 161H L V...

Page 2: ...ith the unit Treat all its constituent parts confidentially They are protected by copyright They may not be reproduced transmitted copied stored in electronic systems or translated into another langua...

Page 3: ...ng and venting the system 20 24 Insulating the hydraulic connections 20 25 Installing the control unit 21 26 Installation and removal of the screen 22 27 Overflow valve 23 28 Commissioning 24 29 Maint...

Page 4: ...ended for all users of the product The operation of the product via the heating and heat pump control and work on the product which is intend ed for end customers operators is suitable for all age gro...

Page 5: ...prevent injuries caused by the rotating fan air duct outlet above ground level weather louvre air duct outlet below ground level rain louvre each not included in the accessories supplied IMPORTANT It...

Page 6: ...he same technology only with reversed benefits The refrigerator extracts heat from food It discharges this heat into the room through fins at its rear The heat pump extracts heat from our environment...

Page 7: ...the control element of the heating and heat pump controller to operate and control the heat pump system NOTE Make sure that the controller settings are correct Operating manual of the heating and hea...

Page 8: ...ery for outwardly visible signs of damage 2 Check to make sure that the delivery is complete Any defects or incorrect deliveries must be report ed immediately NOTE Note the unit model Check the direct...

Page 9: ...plans for air water heat pumps The respective regional regulations must be observed Installation room and space requirements NOTE Note and follow the local regulations and standards regarding the ins...

Page 10: ...can also transport the heat pump on a handcart or with tube handles Lifting the unit with tube handles page 10 WARNING The unit is not fixed on the wooden pallet Risk of tipping overturning during tra...

Page 11: ...tion Make sure that the unit s baseframe is in full contact with the surface of the floor 7 Remove the tube handles 8 If the electrical connection work is not carried out immediately re attach the low...

Page 12: ...hem in a safe place 5 At the fan thread in the two guide rods supplied with the unit through the metal tab and fan Then on both sides hook the guide rods in the key hole perforation of the top metal t...

Page 13: ...stening nuts on the top metal tab and remove the corresponding bolts Then pull the fan out of the unit and bolt it back onto the unit frame do not forget the spring lock washers 10 Remove the guide ro...

Page 14: ...rence between the vertical centre of the air duct connections on the unit and the top edge of the air inlet air out let on the building must not exceed 2 m 4 Turn the already pushed together parts thr...

Page 15: ...ip on the mounting strip and use special screws to fix onto the places provided for this purpose on the air duct for the air inlet side 2 Glue the connection frame supplied onto the edge of the air du...

Page 16: ...procedure 2 4 at the air outlet side Installing the frame trim Screw the frame trim onto the wall penetration on the air inlet and air outlet side NOTE The frame trim does not fulfil any technical fu...

Page 17: ...heating circuit IMPORTANT Integrate the unit in the heating circuit as shown in the hydraulic diagram for the respective unit model It is not possible to connect several heat pumps in parallel Hydrau...

Page 18: ...d guidelines Also install filling and draining emptying devices shut off devices and non return valves in the heating circuit 18 Circulation pump The circulation pump is installed in the unit Only one...

Page 19: ...ned draw ing for the respective unit model 3 2 Push the cables through the rubber grommets in the unit By pushing them in the cables are routed inside the unit in a closed cable duct to the terminals...

Page 20: ...nly low salt operation of the system Advantages of low salt operation Low corrosion promoting properties No formation of mineral scale Ideal for closed heating circuits Ideal pH value due to self alka...

Page 21: ...to position 3 Push the control cable of the heating and heat pump controller into the right socket on the un derside of the control unit NOTE A connection to a computer or a network can be made via th...

Page 22: ...ment 2 logo 3 temporary cover 1 First insert the screen below in the provided slots on the front of the facade 2 Beginning first on one side and moving upwards lock the screen s snap in lugs in place...

Page 23: ...ivated The UWP control signal is the indication of the currently required pump capacity in If the flow rate is the current flow rate measuring accuracy 200 l h 1 Fully open the overflow valve close th...

Page 24: ...rer s factory customer service department In other countries Send completion report for heat pump systems and general checklist to the manufacturer s local partner 4 The heat pump system is commission...

Page 25: ...al cleaning agent any residues must be neu tralised and the system flushed intensive ly with water Always note and follow the technical data of the respective heat ex changer manufacturer 30 Malfuncti...

Page 26: ...tling DANGER Risk of fatal electric shock All electrical connection work must be carried out by qualified electricians only Before opening the unit disconnect the system from the power supply and prev...

Page 27: ...perating pressure bar 3 Circulation pump control range min I max l h 1000 2000 General unit data Total weight kg 367 Weight of heat pump module Compact module Fan module kg kg kg Refrigerant type Refr...

Page 28: ...1 823295 Legende NEU Volumenstrom Heizwasser Temp Temperatur W rmequelle Qh min max minimale und maximale m gliche Heizleistung p Freie Pressung W rmepumpe LW 160H L V 823295 Datei 823295 Leistungs Dr...

Page 29: ...5 4 DIN ISO 228 3 Heating water inlet return G 5 4 DIN ISO 228 4 Bushings for electrical sensor cables 5 Condensate hose Length from unit 1 m inside 30 Keys UK819355a All dimensions in mm Pos Name A F...

Page 30: ...5 4 DIN ISO 228 3 Heating water inlet return G 5 4 DIN ISO 228 4 Bushings for electrical sensor cables 5 Condensate hose Length from unit 1 m inside 30 Keys UK819356a All dimensions in mm Pos Name A F...

Page 31: ...installation in the light well Tipping dimension of the heat pump 2050 Pos Name Dim B1 If finished wall thickness 240 to 320 2340 If finished wall thickness 320 to 400 2260 B2 If finished wall thickn...

Page 32: ...installation in the light well Tipping dimension of the heat pump 2050 Pos Name Dim B1 If finished wall thickness 240 to 320 2340 If finished wall thickness 320 to 400 2260 B2 If finished wall thickne...

Page 33: ...the light well Tipping dimension of the heat pump 2050 Pos Name Dim B2 If finished wall thickness 240 to 320 390 If finished wall thickness 320 to 400 310 1 Accessories Wall duct 1000x1000x420 3 Acce...

Page 34: ...densate drain G Detail of installation in the light well Tipping dimension of the heat pump 2050 Pos Name Dim B2 If finished wall thickness 240 to 320 390 If finished wall thickness 320 to 400 310 1 A...

Page 35: ...LW 161H L V IMPORTANT The minimum distances necessary for correct and safe operation as well as any service work must be ob served 9 Air intake on the side facing away from the coast from the prevaili...

Page 36: ...36 Subject to change without notice 83061600bUK ait deutschland GmbH Row tank LW 161H L V...

Page 37: ...37 Subject to change without notice 83061600bUK ait deutschland GmbH 23 ZUP Separate buffer tank LW 161H L V...

Page 38: ...mfort board Expansion board 29 Dirt trap 0 6 mm mesh 15 Mixer circuit three way mixer MK2 3 discharge r o t a l u g e r e c n e r e f f i d e r u t a r e p m e T 7 1 l a n o i t p o g n i l o o c r o...

Page 39: ...xiliary circulation pump Accessories Process water sensor thermostat Heating circuit circulating pump External sensor Hot water gauge thermostat Sensor mixing circuit 1 External return sensor Return s...

Page 40: ...rminal in switch box heat pump 1 G1 E23 F6 PFC X10 3 M1 R6 F1 1 2 3 4 5 6 7 8 1 2 8 A B C D E F A B C D E F Blatt Bl 1 4 3 4 5 6 7 AIT Stromlaufplan ait deutschland GmbH PEP012 2017 08 01 2018 AP 1N P...

Page 41: ...J20 STB Q6 J15 J22 X20 J11 K22 J7 K23 1 2 3 4 5 6 7 8 1 2 8 A B C D E F A B C D E F Blatt Bl 2 4 3 4 5 6 7 AIT Stromlaufplan ait deutschland GmbH PEP012 2017 08 01 2018 AP N 1 A4 L L N N PE PE 1 B3 13...

Page 42: ...sensor Heat source input sensor B10 817453b B11 J13 X100 R3 R2 R1 J21 R5 R4 SEC Board 1 2 3 4 5 6 7 8 1 2 8 A B C D E F A B C D E F Blatt Bl 3 4 3 4 5 6 7 AIT Stromlaufplan ait deutschland GmbH PEP01...

Page 43: ...Blatt Bl 4 4 3 4 5 6 7 AIT Stromlaufplan ait deutschland GmbH PEP012 2017 08 01 2018 AP PE 2 D6 N 2 D6 L 2 D6 PE N L br bl HUP PE OUT8 OUT7 OUT6 OUT5 OUT4 OUT3 OUT2 OUT1 N N L IN1 IN2 IN3 IN4 IN5 L L...

Page 44: ...44 Subject to change without notice 83061600bUK ait deutschland GmbH...

Page 45: ...45 Subject to change without notice 83061600bUK ait deutschland GmbH...

Page 46: ...46 Subject to change without notice 83061600bUK ait deutschland GmbH...

Page 47: ...47 Subject to change without notice 83061600bUK ait deutschland GmbH...

Page 48: ...ait deutschland GmbH Industriestra e 3 D 95359 Kasendorf E info alpha innotec de W www alpha innotec de alpha innotec an ait deutschland GmbH brand UK...

Reviews: