43
We reserve the right to make technical changes | 83055600dUK – Translation of the original instruction manual (HMD 2) | ait-deutschland GmbH
Parameter
Factory setting
Adjustment during
commissioning *)
Value range (adjustable steps) Access
Output heat. max.
100 %
50 % – 100 % (
↕
1) Fitter
Control dhw
Auto
Auto • Manual Fitter
output dhw.
100 %
1 % – 100 % (
↕
1) Fitter
output dhw max
100 %
50 % – 100 % (
↕
1) Fitter
output cooling
100 %
1 % – 100 % (
↕
1) Fitter
dT cooling
5 K
1 K – 5 K (
↕0.
1) Fitter
Set bypass valve
No
No • Yes
User
Second heat generator
Second heat gen. 1
Type
No
No • El.Rod • Boiler • Thermal Fitter
Function
HW a SW
No • HW a SW • Heating Fitter
Position
Integrated
– – – • Integrated • Tank Fitter
Outlet
installation-dependent
– – – • (output contact) Fitter
Second heat gen. 2
Type
No
No • El.Rod Fitter
Function
No
No • Heating • SW Fitter
Position
– – –
– – – • Tank Fitter
Outlet
– – –
– – – • (output contact) Fitter
Pump flow
Pump flow ZUP
60 s
0 – 60 s (
↕
5) Fitter
Smart
Smart Home ID
–
1 – 4 (
↕
1)
User
Heating circuit
No
No • Yes
User
range +
0 K
0 K – 5 K (
↕
1)
User
range –
0 K
0 K – 5 K (
↕
1)
User
mixing circ 1
No
No • Yes
User
range +
0 K
0 K – 5 K (
↕
1)
User
range –
0 K
0 K – 5 K (
↕
1)
User
DHW
No
No • Yes
User
intelligent defrost
No
No • Yes Fitter
Smart Grid
Decrease Heating
-2 K
-0.5 K – -25 K (
↕
0.5) Fitter
Increase heating
2 K
0.5 K – 5 K (
↕
0.5) Fitter
Increase SW
2 K
0.5 K – 10 K (
↕
0.5) Fitter
*) Please enter the adjusted values. If 2 heat pumps are connected, enter both values. Mark not applicable with — .