14 Installation of the control unit
Situated at different heights in the upper facade of the
operating side of the unit are recesses (each with 4 re-
cesses) for the fastening of the control unit:
1 four upper recesses
2 four lower recesses
4 hooks are located on the back side of the control unit
and can be used to hang the control unit on the front
facade of the unit:
1. Hang the control unit’s hooks on the recesses of
the upper facade (either in the upper or lower re-
cesses.
Example: Control unit in upper recesses
2. Push the control unit down until it locks into posi-
tion.
3. Stick the heating and heat pump regulator’s con-
trol cable into the
right
bushing on the bottom of
the control unit.
NOTE
A connection to a computer or a network can
be installed via the left bushing on the bottom
of the control unit, thus allowing the heating
and heat pump regulator to be controlled re-
motely. One pre-condition is that a screened
network cable (category 6) be installed
through the unit when installing the unit.
Operating manual for the heating and heat pump
regulator, part 2, “Web server” section
If this network cable is available, insert the
network cable’s RJ-45 plug into the left bush-
ing of the control unit.
NOTE
The network cable can be exchanged at any
time. In order to be able to connect it, the
screen must first be removed.