___________________________________________________________________
Alpha ESS Co., Ltd.
Page 23
Your Smart Energy
Installation
Step 13-2:
Assemble the AC connector and connect the conductor to the AC
connector
Step 13-3:
Ensure that all conductors are securely connected to the AC connector.
Step 13-4:
Plug the AC connector into the jack for the AC connection.
a. Parts are equipped with cables
b. Crimp the wire according to the position shown, tighten the screw torque0.8
±
0.1N
·
m.
Object
Description
Value
A
External diameter
8 mm to 14 mm
B
Conductor cross-section
2.5 mm² to 4 mm²
C
Stripping length of the insulated
conductors
approx.6.5mm
D
Stripping length of the outer
sheath of the AC cable
approx. 30 mm (Backup)
approx.30mm (Grid L and N)
approx.35mm (Grid PE)
Insert the cables into
the corresponding Pin
holes and tighten the
screws with the
screwdrivers.
c. The plastic core is screwed into the body
L
N
PE
Line male
Male
Female
Main
part
Lock nut
Sealing body