1.1 System Introduction
INTRODUCTION
01
INTRODUCTION
INTRODUCTION
AlphaESS Storion-SMILE-T10 (incl. M4856-S, HV50056 and SMILE-T10-INV) can be
applied in DC-coupled systems (mostly new installation), AC-coupled systems (mostly
retrofit) and Hybrid-coupled systems (mostly retrofit, and PV capacity-increase), as the
following scheme:
Figure 1 DC-coupled Storage System – Scheme
Monitoring
Device
PV
PV
Alpha
Cloud
LAN
Normal Loads
Grid
Grid Meter
Critical Loads
Storion-SMILE-T10
Figure 2 AC-coupled Storage System – Scheme
Figure 4 AC-coupled Storage System – Scheme, Germany >10 kWp
Monitoring
Device
Alpha
Cloud
LAN
Normal Loads
Grid
Grid Meter
Critical Loads
Storion-SMILE-T10
Grid Meter
PV Inverter
PV Inverter
PV
Monitoring
Device
Alpha
Cloud
LAN
Normal Loads
Grid
Grid Meter
Critical Loads
Storion-SMILE-T10
Z1 of Grid
Company
Grid Meter
Z2 of Grid
Company
PV
PV
Figure 3 Hybrid-coupled Storage System – Scheme
Monitoring
Device
Alpha
Cloud
LAN
Normal Loads
Grid
Grid Meter
Critical Loads
Storion-SMILE-T10
Grid Meter
PV Inverter
CAUTION:
For the AC-/ Hybrid-coupled system, unlike DC, two power meters are to be mounted.
In Germany some federal states require that only AC solutions be used if more than 10 kWp
capacity of PV is installed, the meters of grid company must be also installed in the system as
the following figure shows
01
02
01
02