ADM-XRC-7Z1 User Manual
V2.6 - 14th February 2022
.
Target FPGA
Board (uC and PCB)
Min
Lower
Warning
Upper
Warning
Max
Min
Lower
Warning
Upper
Warning
Max
Commercial
-5°C
+5°C
+80°C
+90°C
-5°C
+5°C
+65°C
+75°C
Extended
-5°C
+5°C
+95°C
+105°C
-5°C
+5°C
+80°C
+90°C
Industrial
-45°C
-35°C
+95°C
+105°C
-45°C
-35°C
+80°C
+90°C
Table 22 : Temperature Limits
4.10.2 System Monitor Status LEDs
LEDs D5 (Green) and D6 (Red) indicate the microcontroller status.
LEDs
Status
Flashing Green + Flashing Red (alternate)
Service Mode
Red
Missing application firmware or invalid firmware
Red + Green
Standby (Powered off)
Green
Running and no alarms
Flashing Green + Red
Attention - alarm active
Flashing Green + Flashing Red (together)
Attention - critical alarm active
Flashing Red
FPGA configuration cleared to protect board
Table 23 : System Monitor Status LEDs
Page 20
Functional Description
ad-ug-1253_v2_6.pdf