Option 2

56-92 Zone System:

• Each card installed will have 6 ports

• On top of each port there is a label indicating connection:

S01-S_

 is the port used for connecting emergency phones

TD(1-2)(3-4) with a dot under the D

 is the port used for connecting Command Center phone(s)

TD(1-2)(3-4) with a dot under the T

 is the port used for outside Telco line

• Plug the supplied RJ45 pigtail cables into the ports following the wiring chart and pin-out color scheme

  below

• Refer to the top of the cards to see what type of port and number of extensions

• The same pin-out color scheme should be used for the primary card and for all additional cards. The

system uses T568-A for pin-out wiring.

• The first card installed will always be:

• Port 1: (S01-S04) Connection for 4 Emergency Phones

• Port 2: (S05-S08) Connection for 4 Emergency Phones

• Port 3: (S09-S12) Connection for 4 Emergency Phones

• Port 4: (S13-S16) Connection for 4 Emergency Phones

• Port 5: (D1-2) Connection for up to 2 Command Center Phones

• Port 6: (T1-2) Connection for up to 2 outside Telco Lines

Card 1 Example

 pg. 6

S01-S04

S05-S08

S09-S12

2003

2004

COMMAND CENTER 1

SECONDARY COMMAND CENTER 

OR BUTTON CONSOLE

2001

2002

PHONE 1

PHONE 2

PHONE 3

PHONE 4

Note: Do not use 

the green and 

brown pairs

S13-S16

D1-2

T1-2

2007

2008

2005

2006

PHONE 5

PHONE 6

PHONE 7

PHONE 8

2011

2012

2009

2010

PHONE 9

PHONE 10

PHONE 11

PHONE 12

2015

2016

2013

2014

PHONE 13

PHONE 14

PHONE 15

PHONE 16

TELCO LINE 1

TELCO LINE 2

Summary of Contents for AlphaRefuge 2400 Series

Page 1: ...42 Central Drive Farmingdale NY 11735 631 777 5500 800 666 4800 www alphacommunications com AWD266 Rev 07 18 Made in the USA Installation Operations Manual 2400 Series...

Page 2: ...he diagram below for attaching the extender and foot stand to the back of the Command Center phone as needed Page 2 Installation Included Command Center Phone with phone line cable Distribution Module...

Page 3: ...nection to Card 1 Extension 2002 Orange and White Orange Stripe Two Wire Connection to Card 1 Extension 2001 Blue and White Blue Stripe N56W24720 N Corporate Circle Sussex WI 53089 800 451 1460 www ra...

Page 4: ...ication wire pair should be connected to the red and green screw terminals on the biscuit jack This will prevent loose connections that can cause the system to malfunction Option 1 12 36 Zone System O...

Page 5: ...Port 1 01 04 Connection for 4 Emergency Phones Port 2 05 06 Connection for 2 Emergency Phones Port 3 07 08 Conneciton for 2 Emergency Phones Note The numbering pattern continues on cards 3 through 5...

Page 6: ...r all additional cards The system uses T568 A for pin out wiring The first card installed will always be Port 1 S01 S04 Connection for 4 Emergency Phones Port 2 S05 S08 Connection for 4 Emergency Phon...

Page 7: ...ones Port 6 19 20 Conneciton for 2 Emergency Phones Note The numbering pattern continues on cards 3 through 5 Card 6 will always be used for the Voicemail Card and will have no connections S01 S04 S05...

Page 8: ...ial 1002 followed by the appropriate time zone code Eastern Time Zone 111 Central Time Zone 112 Mountain Time Zone 113 Pacific Time Zone 114 b Touch the GREEN button in the middle of the phone when fi...

Page 9: ...w the directions below to program the Command Center Phone to dial the external number a Press the speaker phone button b Dial 1 3 4 c Dial 9 then the external number d To exit Program Mode dial 00 fo...

Page 10: ...1 Select the desired flashing blue LED and press the buttons 2 Each call must be disconnected individually Note If you hang up the handset before disconnecting each call the LED s will remain illumin...

Page 11: ...uired to dial out of your building Phone will make internal calls but not external calls Check the phone line is connected to the correct port on the Distribution Module Verify the phone line by makin...

Reviews: