Step 4

Plug one end of the Distribution Module Power Cable into the DC Adapter Port on the Distribution 

Module. Plug the other end into the 

Alpha Communicatuions

® model 

PWRAPC

 

Series 

Power Supply.

Step 5

Turn on the Power Supply.

Step 6

Turn on the Distribution Module.

Setting the Date and Time

Step 7

Perform the following steps on the Command Center handset.

1. Enter Program Mode

a. Dial 

1#91

b. Enter Password: 

7284

2. Program Time Zone:

a. Dial 

1002

 followed by the appropriate time zone code:

Eastern Time Zone = 

111

Central Time Zone = 

112

Mountain Time Zone = 

113

Pacific Time Zone = 

114

b. Touch the 

GREEN

 button in the middle of the phone when finished

3. Program the Date (month-day-year format):

a. Dial 

1001

 followed by the date

Example: 1001 02152011 for February 15, 2011

b. Touch the 

GREEN

 button in the middle of the phone when finished

4. Program the time (military time including hour-minute-second):

a. Dial 

1003 

followed by the time

Example: 1003 143000 for 2:30pm

b. touch the 

GREEN

 button in the middle of the phone when finished

5. To exit Program Mode dial 

00

 followed by the 

GREEN

 button

Summary of Contents for AlphaRefuge 2400 Series

Page 1: ...42 Central Drive Farmingdale NY 11735 631 777 5500 800 666 4800 www alphacommunications com AWD266 Rev 07 18 Made in the USA Installation Operations Manual 2400 Series...

Page 2: ...he diagram below for attaching the extender and foot stand to the back of the Command Center phone as needed Page 2 Installation Included Command Center Phone with phone line cable Distribution Module...

Page 3: ...nection to Card 1 Extension 2002 Orange and White Orange Stripe Two Wire Connection to Card 1 Extension 2001 Blue and White Blue Stripe N56W24720 N Corporate Circle Sussex WI 53089 800 451 1460 www ra...

Page 4: ...ication wire pair should be connected to the red and green screw terminals on the biscuit jack This will prevent loose connections that can cause the system to malfunction Option 1 12 36 Zone System O...

Page 5: ...Port 1 01 04 Connection for 4 Emergency Phones Port 2 05 06 Connection for 2 Emergency Phones Port 3 07 08 Conneciton for 2 Emergency Phones Note The numbering pattern continues on cards 3 through 5...

Page 6: ...r all additional cards The system uses T568 A for pin out wiring The first card installed will always be Port 1 S01 S04 Connection for 4 Emergency Phones Port 2 S05 S08 Connection for 4 Emergency Phon...

Page 7: ...ones Port 6 19 20 Conneciton for 2 Emergency Phones Note The numbering pattern continues on cards 3 through 5 Card 6 will always be used for the Voicemail Card and will have no connections S01 S04 S05...

Page 8: ...ial 1002 followed by the appropriate time zone code Eastern Time Zone 111 Central Time Zone 112 Mountain Time Zone 113 Pacific Time Zone 114 b Touch the GREEN button in the middle of the phone when fi...

Page 9: ...w the directions below to program the Command Center Phone to dial the external number a Press the speaker phone button b Dial 1 3 4 c Dial 9 then the external number d To exit Program Mode dial 00 fo...

Page 10: ...1 Select the desired flashing blue LED and press the buttons 2 Each call must be disconnected individually Note If you hang up the handset before disconnecting each call the LED s will remain illumin...

Page 11: ...uired to dial out of your building Phone will make internal calls but not external calls Check the phone line is connected to the correct port on the Distribution Module Verify the phone line by makin...

Reviews: