Items Needed
Step 1
Mount the Distribution Module and Power Supply with the battery backup in an appropriate location, install-
ing the cabinet for wall mount units or the stand for desk mount units accordingly. Then remove the knock
outs (if applicable). The recommended location to mount the Distribution Module and Power Supply is in a
network closet or machine room. Mount the Command Center according to the owner’s specifications.
Follow the diagram below for attaching the extender and foot stand to the back of the Command Center
phone as needed.
Page
2
N56W24720 N. Corporate Circle Sussex, WI 53089
800-451-1460 262-246-4828 (fax)
www.rathmicrotech.com www.area-of-refuge.com
Installation
Included
• Command Center Phone with phone line cable
• Distribution Module
• System wiring (pigtail cables, power cord, ethernet cable for programming if needed)
• Cabinet (wall mount) or Stand (desk mount)
Not Included
• 22 or 24 AWG twisted, shielded cable
• Multimeter
• Analog phone for troubleshooting
• Recommended: Biscuit jack for each phone (if needed; not applicable for elevator systems)
Step 2
For 12-36 zone systems, remove the screws on the back of the Distribution Module and remove the cover to
expose the internal ports.