Troubleshooting

Problem

Possible Cause & Solutions

Command Center 

will not power on:

• Check wires for voltage. It should be 28vdc

• If no voltage is detected, confirm you are connected to the DKP port

on the Distribution Module

• If you have 48vdc, you are incorrectly connected to an SLT port

Emergency Phones 

will not call out:

• Check wires for voltage. It should be 48vdc

• If no voltage is detected, confirm you are connected to the SLT port

on the Distribution Module. Note: some SLT ports only use the blue

and orange pairs

• If you have 28vdc, you are incorrectly connected to the DKP port

• Make sure you dial any access digit that may be required to dial out

of your building

Phone will make 

internal calls, but not 

external calls:

• Check the phone line is connected to the correct port on the

Distribution Module

• Verify the phone line by making sure it has 48-52vdc on the line and

use an analog phone to verify you are able to call in and out

Insufficient volume 

on call boxes:

• To adjust the volume on SmartPhones, turn the VR1 port

• To adjust the volume on 2400 Phones, use the VOL key

Lights continuously 

blink on button for 

call box:

• The phone is not properly hung up. Lift the Command Center

handset, select the blinking light, then hang up the handset

Lights periodically 

blink on Command 

Center:

• This indicates the phone is doing a phone line check. This is a

normal function of the system and no action is needed

• To disable this function, refer to the SmartPhone Programming Guide

Summary of Contents for AlphaRefuge 2400 Series

Page 1: ...42 Central Drive Farmingdale NY 11735 631 777 5500 800 666 4800 www alphacommunications com AWD266 Rev 07 18 Made in the USA Installation Operations Manual 2400 Series...

Page 2: ...he diagram below for attaching the extender and foot stand to the back of the Command Center phone as needed Page 2 Installation Included Command Center Phone with phone line cable Distribution Module...

Page 3: ...nection to Card 1 Extension 2002 Orange and White Orange Stripe Two Wire Connection to Card 1 Extension 2001 Blue and White Blue Stripe N56W24720 N Corporate Circle Sussex WI 53089 800 451 1460 www ra...

Page 4: ...ication wire pair should be connected to the red and green screw terminals on the biscuit jack This will prevent loose connections that can cause the system to malfunction Option 1 12 36 Zone System O...

Page 5: ...Port 1 01 04 Connection for 4 Emergency Phones Port 2 05 06 Connection for 2 Emergency Phones Port 3 07 08 Conneciton for 2 Emergency Phones Note The numbering pattern continues on cards 3 through 5...

Page 6: ...r all additional cards The system uses T568 A for pin out wiring The first card installed will always be Port 1 S01 S04 Connection for 4 Emergency Phones Port 2 S05 S08 Connection for 4 Emergency Phon...

Page 7: ...ones Port 6 19 20 Conneciton for 2 Emergency Phones Note The numbering pattern continues on cards 3 through 5 Card 6 will always be used for the Voicemail Card and will have no connections S01 S04 S05...

Page 8: ...ial 1002 followed by the appropriate time zone code Eastern Time Zone 111 Central Time Zone 112 Mountain Time Zone 113 Pacific Time Zone 114 b Touch the GREEN button in the middle of the phone when fi...

Page 9: ...w the directions below to program the Command Center Phone to dial the external number a Press the speaker phone button b Dial 1 3 4 c Dial 9 then the external number d To exit Program Mode dial 00 fo...

Page 10: ...1 Select the desired flashing blue LED and press the buttons 2 Each call must be disconnected individually Note If you hang up the handset before disconnecting each call the LED s will remain illumin...

Page 11: ...uired to dial out of your building Phone will make internal calls but not external calls Check the phone line is connected to the correct port on the Distribution Module Verify the phone line by makin...

Reviews: