background image

The continuous light will illuminate green and the display will show   “CO”.

To switch back to normal humidistat operation, use the arrow keys to

move the setpoint above 36%. 

4. Manual Drain Button  

 

If you need to store or move your dehumidifier, press the “Drain” button to remove water 

from the integral pump’s reservoir.    

Indicator Lights

1. Humidity Display Screen

The display screen has two functions:

        1. When the unit is powered on, it shows the humidity of the space
        2. When setting the desired humidity level, the screen will show the set point. 
        After a brief delay, it will revert to current humidity of the space. 

2. Power Indicator Light

This light indicates that the unit is properly powered on and ready to operate. 

Always make sure the unit is “off” prior to performing any service, unless otherwise indicated.

If the humidity is above the setpoint, the light will be solid green and the machine will 

operate.

If the humidity is below the setpoint, the unit will be in standby mode and the light will be 

flashing. 

3. Continuous Mode/ Auto Defrost Light

When the light illuminates green, it indicates that the dehumidifier is set to continuous 

operation mode.
• When the light illuminates red, it means the unit is in auto defrost mode and clearing the 
evaporator coils of any ice buildup.

4. Compressor Light 

When the light illuminates red, it indicates the compressor has been initiated but is currently 

warming up. 
• Once the light switches to green, it means the compressor is currently in working status.

5

Summary of Contents for Sentinel HDi120

Page 1: ...AlorAir Solutions INC Sentinel HDi120 Specifications subject to change without notice Add 14752 Yorba Ct Chino CA 91710 US...

Page 2: ...it Works Installation Requirements Installation Key Functions Indicator Lights Remote Control Operating Instructions Unit Diagram Maintenance Dehumidifier Storage Ducted Applications Troubleshooting...

Page 3: ...a grounded electrical connection as required for all electrical appliances The use of non grounded wiring will void the warranty Your dehumidifier should only be repaired by a qualified technician Do...

Page 4: ...t air diffusion install the unit so that a side panel faces the wall Alorair dehumidifiers are only intended for operation when the unit is upright and level with the feet on the ground AlorAir dehumi...

Page 5: ...ace the unit on a level surface and wait a minimum of 2 hours before proceeding Key Functions 1 Power Key illuminate green solid or flashing depending on mode Press the power button a second time and...

Page 6: ...dicates that the unit is properly powered on and ready to operate Always make sure the unit is off prior to performing any service unless otherwise indicated If the humidity is above the setpoint the...

Page 7: ...Press the on off button and the machine will start running two beeps Press the button again to turn the machine off 2 Up Button Down Button Use the up and down arrows to adjust the humidity level 3 Mo...

Page 8: ...wer button again and the dehumidifier will stop Note that the fan will continue to operate for 1 minute after the unit has shut off The AlorAir Sentinel HDi120 has an integrated condensate pump During...

Page 9: ...Unit Diagram Front View Back View Control Panel Handle Side Panel Pre filter Discharge Grille Power Cord Ventilation Fan Port Optional Remote Control Drain Hose Connection Auxiliary Terminals 8...

Page 10: ...n The pump requires routine maintenance that is not covered by the warranty Preventative maintenance is necessary to prevent issues from dirt and slime that may accumulate in the drain system This inc...

Page 11: ...owels can be used to remove any remaining water 2 Unplug the dehumidifier and remove the cover so you have access to the pump 3 Remove the pump head from the reservoir by unscrewing the screw Wipe res...

Page 12: ...ted Applications Ducting the dehumidifier allows the unit to be in one room while conditioning an adjacent room Both the inlet return grille and the supply grille are designed for 10 flex ducting Duct...

Page 13: ...that both ends of the power cord are plugged in Power Outage Reset power Trouble Code LO Clean the filter Clear the blockage Filter is Dirty Air Inlet or Outlet is Blocked Diaplay is Blank No AirFlow...

Page 14: ...MERV 1 filter AlorAir MERV 10 filter...

Page 15: ...Limited Warranty Exclusions...

Reviews: